Removing, installing and checking control unit J604 (with Z35): Audi Q7 (4M)
Removing, installing and checking control unit J604 (with Z35) — Audi Q7 (4M). 31 source steps. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi Q7 (4M, 2015–)
Don't miss
- On vehicles with right-hand drive, move the driver's seat to the rearmost position and remove the dash panel (because of the defroster flap control motor V107Removing and installing defroster flap control motor V107 .
- The fitting location of the fuse can be found in the relevant current flow diagram .
- After detaching, insulate the two wires (B) and (C) separately (risk of short circuit).
📋 Procedure
- Switch on ignition.
- Set the air outflow direction on the front air conditioner operating and display unit E87 to "“DEF”" (to windscreen).
- Set the temperature on the E87 for the right side to "“warm”" (only with a "“Low”" or "“Mid”" air conditioner).
- Move the front right seat (front passenger's seat) as far back as it will go.
- Switch off ignition.
- Remove glove box General body repairs, interior 68. Shelves / trim panels; Removing and installing glove box. [Note: On vehicles with right-hand drive, move the driver's seat to the rearmost position and remove the dash panel (because of the defroster flap control motor V107Removing and installing defroster flap control motor V107 .]
- Remove right footwell vent (front passenger's side) (see the separate procedure).
- If available, remove air duct for glove box cooling (see the separate procedure).
- Remove fresh air blower V2 (with fresh air blower control unit J126) (not on vehicles with right-hand drive)
- ⚠ Risk of short circuit when disconnecting the power supply to the auxiliary air heater element Z35.Remove the fuse in the power supply to the auxiliary air heater element Z35.Before unscrewing the hexagon nuts, use a voltage detector to check that they are not connected to a live voltage. — Interrupt the power supply to the auxiliary air heater element Z35 by removing the corresponding fuse (currently 150 A). [Note: The fitting location of the fuse can be found in the relevant current flow diagram .]
- Remove brackets for right control motors Removing and installing retainers for right control motors (with a "Mix" or "High" air conditioner).
- Detach connector from control motor V427 / V443.
- Unplug the connector (A) from the supplementary air heater control unit J604(D).
- Check again using a voltage tester. There must not be any voltage between the connections (C) (positive) and (B) (negative) (danger of short circuit). [Note: To prevent interchange of the connections (C) (positive) and (B) (negative), the diameters are different (M6 thread and M8 thread on J604).If the connections ((C) and (B)) are incorrectly assigned, J604 can no longer regulate the current and there will be a constant flow of current through Z35 (unregulated with maximum heat output).]
- Detach the two wires (B) and (C) to J604.
- After detaching, insulate the two wires (B) and (C) separately (risk of short circuit).
- Remove bolts (E).
- ⚠ The auxiliary air heater element Z35 may be hot. If Z35 has been activated prior to removal, do not touch Z35. — Pull J604(D) (with Z35, cannot be checked and replaced separately) out of the mounting slot of the heater and air conditioning unit.
- Unscrew bolts (B) and remove the cover (A) for the right heat exchanger.
- With the cover (A) removed, check the mounting slot (C) of the heater and air conditioning unit (with the heat exchanger) for dirt and clean if necessary.
- Check the foam seals on the heat exchanger through the mounting slot (C) (with cover (A) removed). [Note: Removing cover (A) for the right heat exchanger provides a better view into the mounting slot for the J604 as well as of the heat exchanger. The foam seal (B) separates the left and right side of the heat exchanger (A). The foam seal (C) separates the air duct for the front and rear.]
- Check foam seals (B) and (C) as well as the visible part of foam seal (D) on heat exchanger (A) for damage.
- Check that foam seals (B) and (C) are affixed correctly to heat exchanger (A). [Note: If foam seals (B) and (C) are damaged or not affixed correctly, they may come loose when the J604 is inserted (with the Z35) and cause problems in separating and regulating the output temperatures on the left and right side as well as between the front and rear while the air conditioner is operating, depending on the setting of the front air conditioner operating and display unit E87. It may also generate noise. If foam seals (B) or (C) are not affixed correctly, make sure they are affixed securely or replace them Electronic parts catalogue. If damaged, replace foam seals (B)(C) or (D)Electronic parts catalogue.]
- Check that foam seal (C) on auxiliary air heater element Z35(B) is undamaged and affixed correctly [Note: If foam seal (C) is damaged or not affixed correctly, it may come loose when the J604 is inserted (with the Z35) and cause problems in separating and regulating the output temperature for the front and rear while the air conditioner is operating, depending on the setting of the E87. It may also generate noise. If foam seal (C) is not affixed correctly, make sure it is affixed securely or replace it Electronic parts catalogue. If damaged, replace the foam seal (C)Electronic parts catalogue.]
- Check that bonded rubber bushes (D) on the lug (E) of the Z35(B) are seated securely.
- Insert J604(D) (with Z35) into the mounting slot of the heater and air conditioning unit.
- Tighten bolts (E).
- Attach the two wires (B) and (C) to J604.
- Perform basic setting and final control diagnosis for the air conditioner in "“Guided Fault Finding”" mode. [Note: The control motors on this vehicle are equipped with electronics. A new control motor only learns its position at the heater and air conditioning unit in the course of basic setting and can then be activated by the front air conditioner operating and display unit E87 (all control motors are identical at present) in "“Guided Fault Finding”" mode. While you are performing the basic setting, the control motors are assigned and adapted in accordance with the series connection of the wiring. If the sequence is not as specified, the control motors will not be adapted properly and the flaps will not be controlled correctly Overview of control motors of air conditioner.]
- Interrogate the event memory of E87 and erase any faults displayed in "“Guided Fault Finding”" mode.
- After installation, check the activation and operation of Z35 by way of J604 if applicable in "“Guided Fault Finding”" mode and Checking electric supplementary heater.
📐 3 workshop diagrams for this procedure
Drawings linked to this procedure in the workshop data. Locked in the free view.
Other AUDI procedures
- Removing and installing supplementary air heater element Z35 (with supplementary air heater control unit J604)
- Removing, installing and checking auxiliary air heater element Z35 with auxiliary air heater control unit J604
- Checking activation of supplementary heater (auxiliary air heater element Z35)
- Checking actuation of heating element for additional heater Z35
- Checking auxiliary air heater element Z35
- Removing and installing auxiliary air heater element Z35
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.