Removing and installing temperature flap control motor
V68 with potentiometer
G92
Manually controlled air conditioner
Removing
WARNING
Risk of injury from knee airbag.
Before working in the vicinity of pyrotechnic components, the mechanic must
“discharge static electricity”
. Observe the safety precautions for working on airbags (repair group 00: Safety precautions; Safety precautions when working on pyrotechnic components).
Switch off ignition.
Equipment version with ignition lock: Remove ignition key.
Remove dash panel trim or knee airbag (driver side) (repair group 68: Shelves / trim panels; Removing and installing dash panel trim (driver side)).
Remove footwell vent (driver side) (see the separate procedure).
Note
Right-hand drive vehicles: Remove glove box and left footwell vent (repair group 68: Shelves / trim panels; Removing and installing glove box).
Remove bolts (arrows).
Swivel out temperature flap control motor
V68 item 1 behind temperature flap operating shaft (3).
Unplug electrical connector (2).
Detach control motor.
Installing
Installation is carried out in the reverse order; note the following:
Tightening torque (see “Exploded view - heater and air conditioning unit”)
Note
Check operation of flaps and hinge mechanism before installing.
Make sure levers and shafts are seated correctly in actuator sockets.
Position control motor (1) on air distribution housing; gear wheel (2) on control motor must engage in gear wheel (3) at temperature flap lever.
Long tooth (4) must engage in recess (arrow) in actuating arm.
Note
Turn actuator socket in control motor if gear wheels on control motor and temperature flap lever are not opposite one another. Observe notes (see the separate procedure).
The control motor is not positioned correctly on the housing if the bolts cannot be fitted.
Route electrical wiring harness so that it cannot come into contact with moving components (e.g. control motor lever).
To check operation of control motor, connect an adapter cable (see the separate procedure)
, or use a test lead from adapter set
V.A.G 1594C to connect contacts
“5” and
“6” of control motor to a 12 V battery via a 5 A fuse.
Note
Turn control motor until it reaches a convenient position for installation. The direction of rotation can be reversed by interchanging positive and negative.
Install remaining components.
Interrogate event memory and erase any entries displayed; then perform
“Basic setting”
Vehicle diagnostic tester (
“Guided Fault Finding”).
As a final step, check operation of heater/air conditioner.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.