Removing and installing side vent control motor
V262
Note
Mark the motor/flap connecting element on removal to avoid interchange with the connecting elements of the other control motors.
Mark the control motor prior to removal. Pay attention to correct assignment on installation, as well as the correct part number/index on replacement (the various control motors have different electrical values and part number indices)
Electronic parts catalogue.
In the event of the fault
“Upper or lower limit value exceeded”
, check the motor/flap connecting element. It must be properly attached to the motor and there must not be any clearance between the control motor mount and the connecting element. (repair group 70: Dash panel central tube; Exploded view - dash panel central tube)
Removing
Switch off the ignition. (repair group 70).
Note
The central tube is not to be removed.
Screw out the bolts (arrows).
Detach the intermediate piece (A) and lay it aside together with the wiring harness (B) attached to the air duct.
To avoid possible interchange with other identical connectors, mark the connector (C) to the side vent control motor
V262.
Unplug the connector (C) at the side vent control motor
V262 (B).
Screw out the bolts (A).
Detach the side vent control motor
V262.
Note
Inaccessible bolts can be screwed out using the ratchet ring spanner
T40083.
Use a screwdriver to carefully press the connecting element (D) off the side vent control motor
V262 (B).
Note
Leave the connecting element (E) to the side vent shaft in position at the air conditioning unit.
Removing connecting element to shaft for side vent (E) (see the separate procedure).
Installing
Install in reverse order, paying attention to the following:
Check the position of the mount (B) on the control motor shaft (must be in the position shown).
Note
The connecting element (A) is only to be attached in the position in which it engages without having to exert force as shown. If pre-tension is required to attach the connecting element, check whether the mount (B) on the control motor shaft has been turned through 180°.
If the mount (B) on the control motor shaft is not in the position shown, use an adapter lead for example (see the separate procedure) or a test cable from the adapter set
V.A.G 1594C to connect contacts
“5” and
“6” of the control motor by way of a 5 A fuse to a 12 V battery.
Turn the control motor until the mount (B) is in the position shown and the connecting element can be attached without pre-tension. The direction of rotation can be reversed by interchanging positive and negative.
The control motor shaft has no stop. It rotates constantly if voltage is applied between contacts
“5” and
“6” of the control motor connector.
Attach the connecting element (A) for the shaft to the side vent to the side vent control motor
V262 (B).
Install the control motor, paying attention to the correct mutual positioning of the two connecting elements (D) and (E).
Note
In cases of doubt regarding the correct mutual positioning of the two connecting elements (D) and (E)
, use an adapter lead for example (see the separate procedure) or a test cable from the adapter set
V.A.G 1594C to connect contacts
“5” and
“6” of the control motor by way of a 5 A fuse to a 12 V battery. Turn the control motor until an end position is reached (direction of rotation can be reversed by interchanging positive and negative) and in doing so observe the two connecting elements. (repair group 70).
On completion of repair work, perform the following operations on the operating unit,
Climatronic control unit
J255
Vehicle diagnostic, testing and information system
VAS 5051/
, "Guided fault-finding" function:
Interrogate the event recorder and erase any faults displayed.
Implement basic setting.
Implement final control diagnosis.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Removing and installing centre vent control motor V102
- Removing and installing dash panel vent control motor V562
- Removing and installing left centre vent control motor V110
- Removing and installing left side vent control motor V299
- Removing and installing rear left chest vent control motor V315
- Removing and installing rear right chest vent control motor V316
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.