Removing and installing retaining plate with defroster flap control motor V107, left side vent control motor V299 (and left centre vent control motor V110): Audi Q7 (4L)
Removing and installing retaining plate with defroster flap control motor V107, left side vent… Read available instructions and vehicle application notes.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi Q7 (4L, 2005–2015)
- Special tools named: VAS 5051
Don't miss
- After removal, the control motors can be reinstalled only when set in the service position.
- The retaining plate (C) is only installed on vehicles with a "“deluxe”" version of the front operating and display unit (Climatronic control unit J255).
- To remove retaining plate (B), bolts (C) are not loosened or unscrewed. They are designed to guide the retaining plate.
- Mark the connectors (D) to (F) (danger of interchange) and unplug them.
- Bolts (G) are used as a guide when installing the retaining plate. The retaining plate cannot be installed if they are screwed in too far; noise may occur if they are not screwed in far enough.
📋 Procedure
- Switch on ignition.
- Move the control motors to service position by performing air conditioner basic setting (this moves the control motors to "“service position”") "Guided Fault Finding" function of vehicle diagnostic, testing and information system VAS 5051.
- Switch off the ignition as soon as the control motors are in service position "Guided Fault Finding" function of vehicle diagnostic, testing and information system VAS 5051. [Note: After removal, the control motors can be reinstalled only when set in the service position.]
- Remove the bottom left dash panel trim General body repairs, interior70.
- Remove the accelerator pedal module Brake system46.
- Unfasten the relay carrier (with the control units) fitted on the left next to the air conditioning unit and lay it aside Electrical system94 and (repair group 97).
- Detach the left cover from the heat exchanger (see the separate procedure).
- Remove retaining plate (C) with control motors V108 and V158. [Note: The retaining plate (C) is only installed on vehicles with a "“deluxe”" version of the front operating and display unit (Climatronic control unit J255).]
- Unscrew bolts (A). [Note: To remove retaining plate (B), bolts (C) are not loosened or unscrewed. They are designed to guide the retaining plate.]
- Pull retaining plate (B) with control motors out downwards.
- Mark the connectors (D) to (F) (danger of interchange) and unplug them.
- Release fastener for wiring harness (G) from retaining plate (B). [Note: On vehicles with a "“basic”" air conditioner; only the defroster flap control motor V107(H) and the left side vent control motor V299(B) are installed. The left centre vent control motor V110(K) with connector (F) is only installed on vehicles with a "“deluxe”" air conditioner.]
- Check levers of control motors (A) to (C). The retaining plate can only be installed properly if the levers are in the position shown (service position). [Note: (H) shows the respective adjustment range of the control motors. If the levers of the control motors are not in the position shown, the control motor(s) can be connected, e.g. using an adapter cable (or a test lead from the adapter set V.A.G 1594/C, contacts "“5”" and "“6”" of control motor) via a 5 A fuse to a 12 V battery. Turn the control motor until it reaches the position shown (the direction of rotation can be reversed by interchanging positive and negative).]
- Check the position of the threaded plates (J). [Note: Bolts (G) are used as a guide when installing the retaining plate. The retaining plate cannot be installed if they are screwed in too far; noise may occur if they are not screwed in far enough.]
- Plug in the connectors at the control motors (pay attention to assignment, danger of interchange) and attach the wiring harness to the retaining plate.
- Place the retaining plate on the bolts (F), taking care to ensure that the lugs at the levers of the control motors (A) to (C) enter into the guides of the levers at the flaps (D) to (F).
- Slide retaining plate (B) with control motors onto air conditioning unit from underneath.
- Check the routing of the wiring and take care to ensure that the wiring cannot come into contact with moving parts of the control motors and the levers of the flaps when installing the retaining plate.
- Check the position of the bolts (C) and that they are properly fitted in the guides of the retaining plate. If the retaining plate is not positioned firmly enough on the bolts (C), screw the bolts in until there is no further play (do not tighten).
- Fit bolts (A).
- Install retaining plate (C) with control motors V108 and V158 (only fitted on vehicles with "“deluxe”" air conditioner).
- Re-install remaining components in reverse order of removal.
- Interrogate fault memory of front operating and display unit (Climatronic control unit J255) and erase any faults displayed Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
- Perform basic setting and final control diagnosis for air conditioner Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
Other AUDI procedures
- Removing and installing retaining plate with defroster flap control motor V107, left side vent control motor V299 (and left centre vent control motor V110)
- Removing and installing defroster flap control motor V107
- Removing and installing defroster flap control motor V107 with potentiometer G135
- Removing and installing front left defroster and chest vent shut-off flap control motor V200
- Removing and installing front right defroster and chest vent shut-off flap control motor V199
- Removing and installing retaining plate (left-side) with footwell flap control motor V261
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.