Removing and installing refrigerant shut-off valve 1 for hybrid battery N516: Audi
Removing and installing refrigerant shut-off valve 1 for hybrid battery N516 — Audi. Original source text. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
Removing and installing refrigerant shut-off valve 1 for hybrid battery
N516
Vehicles with high-voltage system (hybrid vehicles)
For all work on vehicles with a high-voltage system, note the additional warning instructions for working on such vehicles (see the separate procedure) and (repair group 93: General warning instructions for work on the high-voltage system).
For the following steps, work in the vicinity of high-voltage system components is necessary. Therefore,
“perform a visual inspection of the high-voltage components and wiring to check for damage” (see the separate procedure) and
“note general warning instructions for work on the high-voltage system” (repair group 93: General warning instructions for work on the high-voltage system).
WARNING
Safety hazard: the engine can start unexpectedly.
Before carrying out general work on a vehicle with high-voltage electrical system, switch off the ignition and remove the ignition key from the vehicle.
WARNING
Working on vehicles with high-voltage wiring:
Do not support yourself or tools on high-voltage wiring or associated components --> this can damage the insulation.
High-voltage wiring must not be excessively bent or kinked --> this can damage the insulation.
The round high-voltage connectors are colour-coded with an external coloured ring and are provided with mechanical coding or guide lugs. It is important to observe this coding when joining up the round high-voltage connectors, otherwise the connectors can be damaged.
DANGER!
Risk of fatal injury if high-voltage components are damaged.
Observe the following when working in the vicinity of high-voltage components or wiring:
It is not permitted to use cutting or forming tools, other sharp-edged tools or heat sources such as welding, brazing, soldering, hot air or thermal bonding equipment.
Before starting work, visually inspect the high-voltage components in the areas involved.
Before working in the engine compartment, visually inspect the power and control electronics for electric drive
JX1, electric drive motor
V141, air conditioner compressor
V470 and high-voltage wiring.
Before working on the vehicle underbody, visually inspect the high-voltage wiring and covers.
Before working on the rear section of the vehicle, visually inspect the high-voltage wiring and the electro-box with the maintenance connector for high-voltage system
TW.
Visually inspect all potential equalisation lines.
Check the following when making the visual inspection:
There must be no external damage on any component.
The insulation of the high-voltage wiring and potential equalisation lines must not be damaged.
There must be no unusual deformation of the high-voltage wiring.
All high-voltage components must be identified by a red warning sticker.
Special tools and workshop equipment required
Engine bung set
VAS 6122
Removing
Switch off ignition.
Discharge refrigerant circuit (repair group 87: Refrigerant circuit).
Remove refrigerant line from refrigerant shut-off valve 1 for hybrid battery (see the separate procedure).
Unplug electrical connector (3) and remove from bracket (1).
Counterhold shut-off valve 1 item 2 and unscrew union nut (5).
Pull refrigerant shut-off valve 1 for hybrid battery
N516 off refrigerant line (4).
Seal off open lines and connections with clean plugs from engine bung set
VAS 6122.
Note
Seal open lines and the connections with suitable caps (to prevent damage and the ingress of dirt and moisture).
Installing
Install in reverse order of removal; note the following.
Tightening torque (see “Exploded view - refrigerant lines, expansion valve, internal heat exchanger”)
Note
Observe fitting instructions for O-rings (see the separate procedure).
After attaching, check routing of refrigerant lines. They must be inserted in brackets provided and should not make contact with other components.
Replace the O-rings (see the separate procedure)
; for version, refer to
Electronic parts catalogue.
Screw in union nut by hand until it makes contact.
Install refrigerant line at refrigerant shut-off valve 1 for hybrid battery (see the separate procedure).
Finish tighten the union nuts
1, 3 whilst providing support at the shut-off valve 1
Item 2 (see “Exploded view - refrigerant lines, expansion valve, internal heat exchanger”).
Note
When tightening the union nuts, make sure not to strain the refrigerant lines.
Evacuating and charging refrigerant circuit (repair group 87: Refrigerant circuit).
Re-install remaining components (removed earlier).
Switch on ignition.
Interrogate event memory of operating and display unit (
Climatronic control unit
J255
) and control unit for air conditioning compressor
J842 and erase any faults displayed
Vehicle diagnostic tester in
“Guided Fault Finding” mode.
Start up air conditioner after charging refrigerant circuit (see the separate procedure).
Note
Also observe notes on starting up air conditioner after charging (repair group 87: General information on air conditioner).
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Expansion valve with refrigerant shut-off valve 2 for hybrid battery N517
- Detaching and attaching refrigerant line at refrigerant shut-off valve 1 for hybrid battery N516, vehicles with high-voltage system
- Detaching and attaching refrigerant line at refrigerant shut-off valve 1 for hybrid battery N516
- Removing and installing expansion valve (rear) with refrigerant shut-off valve 2 for hybrid battery N517
- Removing and installing expansion valve with refrigerant shut-off valve 2 for hybrid battery N517, vehicles with high-voltage system
- Removing and installing expansion valve with refrigerant shut-off valve 2 for hybrid battery N517
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.