📋 Procedure

ℹ️ Torque figures below come verbatim from workshop data — always cross-check against your vehicle's factory manual before final tightening.

Removing and installing high-voltage wiring harness for hybrid battery
PX1
The high-voltage wiring harness for hybrid battery
PX1 consists of the following wires:
High-voltage wire for hybrid battery, positive terminal
P1 (red coloured ring)
High-voltage wire for hybrid battery, negative terminal
P2 (brown coloured ring)
WARNING
Working on vehicles with high-voltage wiring:
Do not support yourself or tools on high-voltage wiring or associated components --> this can damage the insulation.
High-voltage wiring must not be excessively bent or kinked --> this can damage the insulation.
The round high-voltage connectors are colour-coded with an external coloured ring and are provided with mechanical coding or guide lugs. It is important to observe this coding when joining up the round high-voltage connectors, otherwise the connectors can be damaged.
Special tools and workshop equipment required
Torque wrench
V.A.G 1331
Release tool
T40258
Removing
De-energise high-voltage system.
The high-voltage system must be de-energised according to the
“Guided Fault Finding” routine in the
Vehicle diagnostic tester
, and ONLY by this method.
DANGER!
High voltage can cause fatal injury
Danger of severe or fatal injuries from electric shock
The high-voltage system may only be de-energised by a suitably qualified person (Audi high-voltage technician).
It must be definitely confirmed that the high-voltage system is de-energised. The system may only be de-energised using the vehicle diagnostic tester via
“Guided Fault Finding”.
The qualified person (Audi high-voltage technician) confirms that the system is de-energised and uses the locking cap
T40262 to ensure that the system cannot be re-energised. The ignition key and the maintenance connector for high-voltage system
TW are then stored in a safe place by the qualified person.
The qualified person (Audi high-voltage technician) marks the vehicle by attaching the appropriate warning signs.
Note
De-energising high-voltage system:
Connect vehicle diagnostic tester
Select
Guided Fault Finding mode
Using the
Go to button, select the following menu options in succession:
Function/component selection
Body
Electrical system
Self-diagnosis-compatible systems
8C - Hybrid battery management -J840
8C - Hybrid battery management, functions
51 - De-energise high-voltage system (Rep. gr. 93)
High-voltage wiring harness for hybrid battery
PX1 is located on left of vehicle underside.
Remove
hybrid battery unit
AX1 (see the separate procedure).
Remove front noise insulation (repair group 66: Removing and installing front noise insulation).
Remove rear noise insulation (repair group 66: Removing and installing rear noise insulation).
Remove underbody cover (repair group 66: Exploded view - covers).
Disconnect high-voltage wiring harness for hybrid battery
PX1 (2) from power and control electronics for electric drive
JX1 (see the separate procedure).
Guide high-voltage wiring harness for hybrid battery
PX1 downwards out of engine compartment.
Cut through cable ties towards rear until wire guides (1) and (2) are reached and unclip high-voltage wiring harness.
Remove wiring guides (1) to (2) (1.5 Nm).
Unscrew nuts (3) (1.5 Nm) on leadthrough (1).
Remove wiring guide (2) (1.5 Nm) and cut though cable ties (arrows).
Unclip leadthrough (3) and guide downwards through body floor.
Guide high-voltage wiring harness for hybrid battery
PX1 (1) through opening in body floor and take out of vehicle downwards.
Installing
Installation is carried out in reverse sequence; note the following:
WARNING
Pay very careful attention to the coding of the high-voltage wires. Mistakes lead to short circuits and irreparable damage to high-voltage components.
Note
All cable ties which have been released or cut through during removal must be re-attached in the same position on installation.
Tighten all screw connections to the tightening torques specified.
When installing leadthrough in luggage compartment floor, make sure that it engages and seals securely.
WARNING
Working on vehicles with high-voltage wiring:
Do not support yourself or tools on high-voltage wiring or associated components --> this can damage the insulation.
High-voltage wiring must not be excessively bent or kinked --> this can damage the insulation.
The round high-voltage connectors are colour-coded with an external coloured ring and are provided with mechanical coding or guide lugs. It is important to observe this coding when joining up the round high-voltage connectors, otherwise the connectors can be damaged.
Coding of high-voltage connectors on hybrid battery unit
AX1
Fig.
Coding of high-voltage connectors on power and control electronics for electric drive
JX1
Fig.
Re-energise high-voltage system.
The high-voltage system must be re-energised according to the
“Guided Fault Finding” routine in the
Vehicle diagnostic tester
, and ONLY by this method.
DANGER!
High voltage can cause fatal injury
Danger of severe or fatal injuries from electric shock.
The high-voltage system may only be re-energised by a suitably qualified person (Audi high-voltage technician).
The system may only be re-energised using the vehicle diagnostic tester via
“Guided Fault Finding”.
The vehicle is then made ready for operation again by the qualified person (Audi high-voltage technician).
The qualified person (Audi high-voltage technician) marks the vehicle by attaching the appropriate warning signs.
Note
Re-energising high-voltage system:
Connect vehicle diagnostic tester
Select
Guided Fault Finding mode
Using the
Go to button, select the following menu options in succession:
Function/component selection
Body
Electrical system
Self-diagnosis-compatible systems
8C - Hybrid battery management -J840
8C - Hybrid battery management, functions
51 - Re-energise high-voltage system (Rep. gr. 93)

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.