TorqFix

Removing and installing evaporator in front heater and air conditioning unit — AUDI

Removing and installing evaporator in front heater and air conditioning unit on Audi: 10 steps. What to remove, in what order, and what to check after.

Workshop procedure for AUDI — the exact step sequence and torque figures, straight from real workshop data.

10 steps

🧭 Before you start

Fits: Audi Q7 (4M, 2015–)

  • Opens: refrigerant (A/C)

📋 Procedure

  1. Switch off ignition.
  2. Discharge refrigerant circuit Air conditioner with refrigerant R134a87Refrigerant circuit.
  3. Remove front heater and air conditioning unit Removing and installing heater and air conditioning unit.
  4. Detach air intake box from heater and air conditioning unit Detaching and attaching air intake box from heater and air conditioning unit.
  5. Detach evaporator housing (A) from air distribution box (B) on front heater and air conditioning unit Attaching and detaching the evaporator housing on the front heater and air conditioning unit.
AUDI? Steps differ between engine variants — check this job against your exact car before you commit to it. Check my car — free →
  1. Remove evaporator (D) from evaporator housing (A)Exploded view - evaporator housing.
  2. Check evaporator housing (A) for dirt, paying special attention to the condensation drain ducts (C) and the evaporator (D) itself.
  3. Attach evaporator housing (A) to air distribution box (B) on front heater and air conditioning unit Attaching and detaching the evaporator housing on the front heater and air conditioning unit.
  4. Perform basic setting and final control diagnosis for the air conditioner in "“Guided Fault Finding”" mode. [Note: The control motors on this vehicle are equipped with electronics. A new control motor only learns its position at the heater and air conditioning unit in the course of basic setting and can then be activated by the front air conditioner operating and display unit E87 (all control motors are identical at present) in "“Guided Fault Finding”" mode.While you are performing the basic setting, the control motors are assigned and adapted in accordance with the series connection of the wiring. If the sequence is not as specified, the control motors will not be adapted properly and the flaps will not be controlled correctly Overview of control motors of air conditioner.]
  5. Start up air conditioner after charging refrigerant circuit Starting up air conditioner after charging refrigerant circuit. [Note: Also observe notes on starting up air conditioner after charging Air conditioner with refrigerant R134a87General notes on air conditioning systems.]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

The figures on this page come from manufacturer workshop documentation and are shown as they are. The page is assembled automatically from that data — it is not written by an AI. The AI works in the chat, where it answers for your specific car. It writes nothing here.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix →

Workshop data on this page last updated 20 Sep 2026.