TorqFix

Removing and installing coolant pipes at Valeo heat exchanger: Audi A3 (8V)

Removing and installing coolant pipes at Valeo heat exchanger — Audi A3 (8V). 19 source steps. Check the document conditions against your vehicle.

19 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A3 (8V, 2012–2020)

Don't miss

  • When performing repairs, a screw-type clip can also be fitted instead of clip (5); (arrow) can be ignored.
  • Check that screw-type clips are seated correctly on connections of heat exchanger and coolant pipes. They must not make contact with air distribution housing or other components.

📋 Procedure

  1. Remove heater and air conditioning unit (see the separate procedure).
  2. Detach sealing collar (3) at plenum chamber partition panel.
  3. Remove bolt (2).
  4. Detach bracket (4) for coolant pipe to the left.
  5. Detach foam (1).
  6. Lift locking element (7), remove securing clip (6) and detach coolant line (top) (5) from heat exchanger.
  7. Remove bolt (8).
  8. Remove screw-type clip (9) and detach coolant line (bottom) (10) from heat exchanger.
  9. Detach coolant pipes.
  1. Check connection (3) of heat exchanger and connection (2) of coolant pipes for damage or dirt.
  2. Clean and smooth sealing surface for O-ring.
  3. Coat new O-ring (4) lightly with coolant (or lubricate lightly with silicone grease) and attach to coolant pipe (1).
  4. Slide coolant pipes into heat exchanger as far as stop.
  1. ⚠ Risk of leaks at heat exchanger. Crushed O-rings and coolant pipes that are not fitted straight or are not attached fully will lead to leaks. — Fit new screw-type clip (2) at connection of coolant pipe to heat exchanger. [Note: When performing repairs, a screw-type clip can also be fitted instead of clip (5); (arrow) can be ignored.]
  1. Tighten bolt (3) to torque.
  2. Check that screw-type clips are seated correctly on connections of heat exchanger and coolant pipes. They must not make contact with air distribution housing or other components.
  3. Install heater and air conditioning unit (see the separate procedure).
  4. Interrogate event memory and erase any entries displayed ("“Guided Fault Finding”").
  5. As a final step, check operation of heater/air conditioner.

📐 2 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 2 workshop diagrams for this job Ask about your Audi — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.