Removing and installing bleeder connection — AUDI
Removing and installing bleeder connection on Audi: 12 steps. What to remove, in what order, and what to check after.
Workshop procedure for AUDI — the exact step sequence and torque figures, straight from real workshop data.
🧭 Before you start
Fits: platform code FV
- Opens: brake fluid, clutch fluid
- Special tools named: 3094
Don't miss
- When performing the following steps, make sure that no brake fluid escapes onto the gearbox. If this does happen, clean the affected area thoroughly.
- Clamping off the supply hose with the hose clamp3094 will cause a permanent deformation.However, this does not damage the supply hose.After removing the hose clamp 3094, the supply hose must be returned to its original shape.
- Catch escaping brake fluid.Do not operate clutch pedal after pipe/hose assembly has been disconnected. — Place lint-free cloth under bleeder connection.
- (Item B) can be disregarded.
📋 Procedure
- Remove air cleaner housing 23Air cleaner; Removing and installing air cleaner housing or 24Air cleaner; Removing and installing air cleaner housing. [Note: When performing the following steps, make sure that no brake fluid escapes onto the gearbox. If this does happen, clean the affected area thoroughly.]
- Place lint-free cloth under clutch master cylinder.
- Using hose clamp3094, clamp off supply hose (2) to clutch master cylinder. [Note: Clamping off the supply hose with the hose clamp3094 will cause a permanent deformation.However, this does not damage the supply hose.After removing the hose clamp 3094, the supply hose must be returned to its original shape.]
- ⚠ Catch escaping brake fluid.Do not operate clutch pedal after pipe/hose assembly has been disconnected. — Place lint-free cloth under bleeder connection.
- Pull out retaining clip (arrow) as far as it will go and disconnect pipe/hose assembly (A) from bleeder connection. [Note: (Item B) can be disregarded.]
- Seal off open lines and connections with clean plugs from engine bung setVAS 6122.
- Release retaining clip (2) with a screwdriver or pointed object and pull bleeder connection (4) off clutch slave cylinder (1).
- Connect pipe/hose assembly (1) to connection .
- Check O-ring (3) at clutch slave cylinder. Push bleeder connection onto connection on clutch slave cylinder so that retaining clip (2) snaps into place.
- Pull on bleeder connection to check it is secure.
- Bleed clutch hydraulics .
- Install air cleaner housing 23Air cleaner; Removing and installing air cleaner housing or 24Air cleaner; Removing and installing air cleaner housing.
Other AUDI procedures
- Removing and installing toothed belt – Audi · 56 torque figures
- Removing engine – Audi A8 D3 · 41 torque figures
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7 · 38 torque figures
- Installing engine – Audi A8 D4 · 36 torque figures
- Removing and installing camshaft timing chain · 29 torque figures
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
The figures on this page come from manufacturer workshop documentation and are shown as they are. The page is assembled automatically from that data — it is not written by an AI. The AI works in the chat, where it answers for your specific car. It writes nothing here.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix →Workshop data on this page last updated 20 Sep 2026.