Incorporation of relay -J541 into vehicle electrical system
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Coolant shut-off valve relay -J541 acts as a control unit. It processes various signals and actuates heater coolant shut-off valve -N279 as well as operating and display unit -E87 on the basis of a range of data.
Coolant shut-off valve relay -J541 can only be actuated by auxiliary heaters for petrol with part number as of index "K" (software version "D50") and this is the only auxiliary heater version which switches on circulation pump when actuated by -J541 (earth applied to connector "B" contact "3"). Such auxiliary heaters were gradually introduced into production as of November 2000 (initially for vehicles with 8-cyl. petrol engine).
Contact · Contact assignment · Function
1 · ▪ Input for data signals from heater control unit -J162 (with additional information in the case of auxiliary heater as of "D50" and code "001XX") / Auxiliary heating/auxiliary ventilation on / Operating status of auxiliary heater (starting, full load, part load, control interval, run-on or auxiliary ventilation) / Coolant temperature in auxiliary heater · ▪ -J541 processes data signal and actuates shut-off valve -N279 and -E87 as a function of coolant temperature supplied and operating status of auxiliary heater
▪ Input for fresh-air blower cut-in signal (for auxiliary heater with "D49" or as of "D50" and code "000XX") / Input signal (approx. battery voltage) for actuation of fresh-air blower by heater control unit -J162 · ▪ 2 s following detection of voltage, -J541 actuates -E87 only; shut-off valve -N279 is not actuated
Notes:
Data signal can only be output by auxiliary heaters as of software version "D50" with code "001XX" for small coolant circuit. Auxiliary heaters with software version "D49" or with software version as of "D50" and code "000XX" for large coolant circuit only output a voltage signal.
If auxiliary heater (as of software version "D50" and code "001XX") is in operating statuses (starting, full load, part load or control interval), coolant shut-off valve is actuated as a function of coolant temperature in auxiliary heater. Operating and display unit -E87 is actuated as soon as coolant temperature supplied exceeds 30 °C.
If auxiliary heater (as of software version "D50" and code "001XX") is in "Auxiliary ventilation" mode, shut-off valve is not actuated but -E87 is actuated immediately.
Contact · Contact assignment · Function
2 · ▪ Output for actuation of heater coolant shut-off valve -N279 (for auxiliary heater as of "D50" and code "001XX") / In auxiliary heating mode with engine stopped, terminal "30" (voltage) is connected to -N279 as a function of coolant temperature in auxiliary heater · / -J541 switches voltage to -N279 and -N279 switches from large to small coolant circuit
▪ Output for actuation of heater coolant shut-off valve -N279 (for auxiliary heater with "D49" or as of "D50" and code "000XX") / In auxiliary heating mode with engine stopped, voltage is not switched to -N279 (application of voltage but no square-wave signal to contact "1") · / -N279 is not actuated (and there is thus no switching to small coolant circuit)
Notes:
Shut-off valve -N279 is actuated in auxiliary heating mode (as of software version "D50" and code "001XX") up to a coolant temperature of approx. 74 °C in auxiliary heater. Actuation is by way of a square-wave signal every 2 seconds. Duty cycle is governed by coolant temperature (approx. 90 % at 63 °C and 0 % at greater than 74 °C).
If auxiliary heater does not output a square-wave signal but rather only a positive signal, -J541 does not actuate -N279. If vehicle is fitted with an auxiliary heater with software version "D49", -J541 (part number 4D0 909 516) cannot be actuated via "Fresh-air blower on" output.
In auxiliary heating mode (with engine stopped), coolant leaving air-conditioner unit heat exchanger is routed directly back to auxiliary heater via shut-off valve -N279 (small circuit) to provide better heating of passenger compartment. If coolant temperature (only applies to auxiliary heaters as of software version "D50" and code "001XX") attains a certain value or if engine is started, shut-off valve is no longer actuated and coolant can flow back to engine (large circuit).
If auxiliary heater is on when engine is started, relay -J541 action is governed by coolant temperature in auxiliary heater (only applies to auxiliary heaters as of software version "D50" and code "001XX"). Switching to large circuit takes place immediately if coolant temperature is greater than 65 °C. If coolant temperature then drops below 60 °C, small circuit is selected again (valve is actuated).
Contact · Contact assignment · Function
3 · ▪ Input for voltage at terminal D+ (for auxiliary heater as of "D50" and code "001XX") / If voltage is less than 5 V (no voltage is applied with engine stopped), shut-off valve -N279 is controlled in line with coolant temperature in auxiliary heater and operating and display unit -E87 switched on as soon as coolant temperature supplied by auxiliary heater is greater than 30 °C · / Voltage is switched to / -N279 and -E87
- If voltage is greater than 5 V, shut-off valve -N279 is only actuated if auxiliary heater was already on when engine was started; switching to small coolant circuit takes place at different temperatures than in auxiliary heating mode · - Voltage is switched to / -N279
- If voltage is greater than 5 V and engine coolant temperature supplied by dash panel insert is less than 80 °C, auxiliary heater circulation pump -V55 is switched on (connection to -J162 not fitted at start of production, introduction not yet finalised) · - Earth is switched to heater control unit -J162, which switches on -V55
Continued ▼
Contact · Contact assignment · Function
3 / Continued · ▪ Input for voltage at terminal D+ (for auxiliary heater with "D49" or as of "D50" and code "000XX") / If voltage is less than 5 V (no voltage is applied with engine stopped), operating and display unit -E87 is switched on, but shut-off valve -N279 is not actuated · / Voltage is switched to -E87
Notes:
Voltage at terminal D+ is used for detection of whether engine is running (voltage is applied if it is).
If voltage is applied to D+ and engine coolant temperature supplied by dash panel insert is less than approx. 80 °C, relay -J541 connects earth to contact 3 at heater control unit -J162 and control unit -J162 switches on circulation pump -V55 (connection to -J162 not fitted at start of production, introduction not yet finalised, designed to improve coolant supply for heat exchanger in air conditioner unit).
Relay -J541 acts as control unit. Method of actuation differs. With auxiliary heaters for petrol with part number as of index "K" (software version "D50"), actuation is also governed by auxiliary heater encoding. Such auxiliary heaters have been gradually introduced into production since November 2000.
Connection between relay -J541 and contact "3" in connector "B" at heater control unit -J162 was not fitted at start of production (introduction not yet finalised).
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
If engine is running and engine coolant temperature transmitted to -J541 by dash panel insert is less than approx. 80°C, relay -J541 connects earth to connector "B" contact "3" at heater control unit -J162 and control unit -J162 switches on circulation pump -V55. Under certain circumstances, this improves coolant supply for air-conditioner heat exchanger and increases heat output.
Contact · Contact assignment · Function
4 · ▪ Earth
5 · ▪ Output for actuation of operating and display unit -E87 (for auxiliary heater as of "D50" and code "001XX") / If "Auxiliary heating mode" is transmitted by heater control unit -J162 with engine stopped, -J541 switches on -E87 as soon as -J162 supplies a coolant temperature greater than 30 °C / If "Auxiliary ventilation mode" is transmitted by heater control unit -J162 with engine stopped, -J541 immediately switches on -E87 · - -J541 switches on -E87 with engine stopped (auxiliary heating/auxiliary ventilation mode)
▪ Output for actuation of operating and display unit -E87 (for auxiliary heater with "D49" or as of "D50" and code "000XX") / If voltage is switched through by heater control unit -J162 with engine stopped, -J541 switches on -E87 · - -J541 switches on -E87 with engine stopped (auxiliary heating/auxiliary ventilation mode)
Contact · Contact assignment · Function
6 · ▪ Power supply, terminal "30"
7 · ▪ Output for actuation of heater control unit -J162 (connection to -J162 not fitted at start of production, introduction not yet finalised) / If coolant temperature less than 80 °C is supplied by dash panel insert with engine running, -J541 connects earth (to -J162) · / -J162 switches on circulation pump as long as earth is applied to contact 3 (only applies to auxiliary heater as of "D50" and code "001XX") / If auxiliary heater starts up as additional heater on starting cold engine on vehicles with petrol engine, heed notes on measured value block "003"
Notes:
If engine is running and engine coolant temperature transmitted to -J541 by dash panel insert is less than approx. 80°C, relay -J541 connects earth via contact 7 to contact 3 at heater control unit -J162 and control unit -J162 switches on circulation pump -V55. Under certain circumstances, this improves coolant supply for air-conditioner heat exchanger and increases heat output.
If auxiliary heater starts up as additional heater on starting cold engine on vehicles with 8-cyl. engine, check adaption of heater control unit -J162. Adaption "1" must be set in adaption channel "10" for software versions "D50" and "D51". As of software version "D52", the adaption setting must be "3". Alter adaption of control unit -J162 if necessary=>Page
01-125.
Connection between relay -J541 (contact 7) and contact "3" in connector "B" at heater control unit -J162 was not fitted at start of production (introduction not yet finalised).
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Output from relay -J541 contact 8 is intended for Audi A8 and is not used with Audi A6.
Contact · Contact assignment · Function
8 · ▪ Output (not used at present) · - With engine running, -J541 connects terminal "30" to this contact
9 · ▪ Input for coolant temperature determined by dash panel insert / If engine coolant temperature supplied by dash panel insert with engine running is less than 80 °C, earth is connected to output, contact 7 at -J541 (this function is not used at present for Audi A6) · / -J541 evaluates coolant temperature and connects earth to contact 7 if necessary (connection to -J162 not fitted at start of production, introduction not yet finalised)
Notes:
Output from relay -J541 contact 7 is intended for Audi A8 and is not used at present with Audi A6.
If engine is running and engine coolant temperature transmitted to -J541 by dash panel insert is less than approx. 80°C, relay -J541 connects earth via contact 7 to contact 3 at heater control unit -J162 and control unit -J162 switches on circulation pump -V55. Under certain circumstances, this improves coolant supply for air-conditioner heat exchanger and increases heat output.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Layout, activation and operation of coolant shut-off valve N82/N422
- Operation of and removing/installing heater coolant shut-off valve N279
- Operation of heater coolant shut-off valve
- Operation of heater coolant shut-off valve N279
- Activation of heater coolant shut-off valve
- Activation of heater coolant shut-off valve N279
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.