TorqFix

Connecting fault reader V.A.G 1551 and selecting function — AUDI

Connecting fault reader V.A.G 1551 and selecting function — Audi. Original source text. Check the document conditions against your vehicle.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

Remove cover for diagnostic connector.
Connect up fault reader V.A.G 1551 with diagnostic wire V.A.G 1551/3 to diagnostic connector.

V.A.G self-diagnosis
HELP
1 - Rapid data transfer*
2 - Flash code output*
Indicated on display:
font=symbol charset=fontspecific code=042 Displayed alternately

Notes:

If there is no display on fault reader V.A.G 1551, use current flow diagram to check wiring of diagnostic connector.

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Depending on the program, additional operating instructions can be printed out by pressing HELP key on V.A.G 1551.
Next step in program sequence can be selected by pressing ⇒key.
Printer is switched on by pressing PRINT key (lamp in key lights).
Fault memory must be interrogated before it can be erased.

Press key -1- for "Rapid data transfer" mode.

Rapid data transfer
HELP
Enter address word XX
Indicated on display:

Press keys -1- and -8- to enter address word 18 for vehicle system to be tested (namely "Additional/auxiliary heater").

Rapid data transfer (Q)
18 - Additional/auxiliary heater
Indicated on display:

Confirm entry with Q key.

Rapid data transfer
Tester transmits address word 18
Indicated on display following entry of address word 18:

4D0 815 071 X
Additional heater Diesel
XXX
Code XXXXX
WSC ZZZZZ
Control unit identification, code and workshop code of V.A.G 1551 are displayed after a brief delay.

The following versions may be fitted, depending on vehicle equipment:
4D0 815 071 X Additional heater Diesel XXX (heater type "Z/C-D" with no recirculating pump -V55)
4D0 265 105 X Auxiliary heater Diesel XXX (heater type "Z/C-D" with recirculating pump -V55)
4D0 265 105 X Auxiliary heater Petrol XXX (heater type "Z/C-B")

Notes:

The first 800 vehicles with diesel engine were fitted with an additional heater for which, instead of the part number 4D0 815 071, the display shows thepart number 4B0 815 071.
Additional heater is only intended for vehicles with diesel engine. On vehicles with petrol and diesel engine, auxiliary heater can also be used as additional heater. Cut-in is automatic on vehicles with diesel engine.
Additional heater can only be switched on when engine is running; undervoltage shutoff is thus not necessary.
The additional heater code number was altered on switching from software version X46 to D47 =>Page
01-30.
Auxiliary and additional heater versions with a control unit with software version "D47/D48" have a different code number to those with a control unit as of software version "D49" =>Page
01-30.
Auxiliary heater versions with control unit with software version "D49" have a different code number to those with a control unit as of software version "D50" =>Page
01-30.

Vehicles with 8-cyl. petrol engine and small coolant circuit for auxiliary heater (gradual introduction as standard as of January 2001) and vehicles with 12-cyl. engine are only to be fitted with auxiliary heaters with part number as of index K (software version as of "D50").
Vehicles with 8-cyl. diesel engine are only to be fitted with auxiliary heaters with part number as of index "J" and software version as of "D52".

Control unit identification (depending on vehicle equipment and encoding, assignment)

=> Parts List

WSC ZZZZZ indicates workshop code of V.A.G 1551 with which encoding / adaption was last performed.
XXX indicates software version of heater control unit -J162.

Note:

Encoding heater control unit -J162 =>Page
01-91

List of functions · Page
01 - Interrogating control unit version · 01-22
02 - Interrogating fault memory · 01-40
03 - Final control diagnosis · 01-57
04 - Basic setting · 01-69
05 - Erasing fault memory · 01-88
06 - End of output · 01-88
07 - Encoding control unit · 01-91
08 - Reading measured value block · 01-106
10 - Adaption · 01-133

Only the functions listed here can be used for auxiliary/additional heater self-diagnosis.

Note:

"Basic setting" function is to be performed for vehicles with auxiliary heater on which temperature-dependent undervoltage cut-out is activated with code "00XX1" =>Page
01-69.

Press ⇒key.

Rapid data transfer
HELP
Select function XX
Indicated on display (function selection, e.g. 02 - Interrogating fault memory):

Notes:

Pressing HELP key prints out a list of possible functions.
Program of V.A.G 1551 returns to start after pressing ⇒key.
If one of the following fault messages appears on the display:

Rapid data transfer
HELP
No control unit response
Press HELP key for printout of possible fault causes.
Rapid data transfer
HELP
K-wire not switched to positive
Use current flow diagram to check diagnostic connector wiring.

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Rapid data transfer
⇒
No signal from control unit

Rapid data transfer
⇒
Fault in communication link
If adjacent display appears at the start of or during the program, faults have occurred and data exchange between fault reader V.A.G 1551 and heater control unit -J162 is no longer possible. Use current flow diagram to check diagnostic connector wiring.

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

After eliminating possible causes of trouble, enter address word 18 for "Additional/auxiliary heater" again and confirm with Q key.

Rapid data transfer
Tester transmits address word 18
Indicated on display following entry of address word 18:
Following display then appears, e.g.:

4D0 815 071 X
Additional heater
XXX
Code XXXXX
WSC ZZZZZ
Control unit identification, code and workshop code of V.A.G 1551 are displayed.

Press ⇒ key.

Rapid data transfer
HELP
Select function XX
Indicated on display (function selection, e.g. 02 - Interrogating fault memory):

Encoding tables

Notes:

As of January 1999, auxiliary/additional heaters with which CO2 level in exhaust gas can be adjusted were gradually introduced (part number is displayed by way of "Control unit identification" function) => Page
82-92.

- Auxiliary heater part number 4D0 265 105 as of index "G" (vehicles with petrol engine)

- Auxiliary/additional heater part no. 4D0 265 105 as of index "H" (vehicles with diesel engine)

- Additional heater part no. 4D0 265 071 as of index "B"

=> Parts List

Auxiliary heaters with part number as of index "J" with software version "D50" have been gradually introduced into production since November 2000 (initially only for vehicles with 8-cyl. petrol engine). Encoding to "small coolant circuit" is possible as of software version "D50".

=> Parts List

If a vehicle provided at the factory with an auxiliary heater with software version "D49" and retrofitted with a small coolant circuit is fitted with an auxiliary heater as of software version "D50", this auxiliary heater is to be encoded - contrary to usual procedure - to "00011" for vehicle with large coolant circuit (no coolant shut-off valve) or vehicle electrical system is to be converted accordingly. => Refer to Page
82-305 and appropriate current flow diagram for vehicles with auxiliary heater and factory-fitted small coolant circuit in Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder (e.g. current flow diagram no. 39 for Model Year 2002 vehicles).

Encoding of additional heater (with control unit -J162 with software version "X46" only):

Code · Significance
0 · 0 · 0 · 0 · 1 · Undervoltage cut-out is effected at voltage value entered in adaption function

Notes:

Additional heaters with software version "X46" were fitted at the start of production.
The additional heater code number was altered on switching from software version "X46" to "D47".
Code "00001" specified by manufacturer is not to be altered.

Encoding of auxiliary/additional heater or additional heater (with control unit -J162 with software version "D47" or "D48"):

Code · Significance
0 · 0 · 0 · 0 · 1 · Undervoltage cut-out is effected at voltage value learnt in basic setting function
0 · 0 · 0 · 0 · 2 · Undervoltage cut-out is effected at voltage value entered in adaption function

Notes:

Code "00002" is always to be entered for heaters used as additional heater only.
Code "00001" is always to be entered for heaters used as auxiliary/additional heater. "00002" is only to be entered if specifically requested by customer => Page
01-91 (encoding control unit).
Software version "D47" or "D48" is used for
- Auxiliary/additional heaters with part number 4D0 265 105 up to index "E" or "F" and for
- Additional heaters with part number 4D0 265 071 up to index "A"
Part number and software version can be called up by way of "Interrogating control unit version" function with fault reader V.A.G 1551.
With code "00001", undervoltage cut-out takes place as soon as battery voltage learnt in "Basic setting" function is not reached in auxiliary heating mode. This temperature-dependent cut-out curve is learnt in "Basic setting" function => Page
01-69.

With code "00002", undervoltage cut-out takes place as soon as battery voltage entered in "Adaption" function is not reached in auxiliary heating mode.
If "Undervoltage cut-out (fixed value)" is displayed as fault for auxiliary/additional heater encoded to "00001":

- Encode auxiliary/additional heater to "00002" => Page
01-91 (encoding control unit).

- Use adaption function to read out value entered for undervoltage cut-out (fixed value) => Page
01-133 (adaption).

- Alter fixed value by way of "Adaption" function (specification less than 10.5 V).

- Encode auxiliary/additional heater to "00001" => Page
01-91 (encoding control unit).

Encoding of auxiliary/additional heater (with control unit -J162 with software version "D49"):

Code · Significance
0 · 0 · 0 · 1 · 1 · - Recirculating pump -V55 fitted / Undervoltage cut-out is effected at voltage value learnt in basic setting function
0 · 0 · 0 · 1 · 2 · - Recirculating pump -V55 fitted / Undervoltage cut-out is effected at voltage value entered in adaption function

Notes:

Code "00011" is always to be entered for heaters used as auxiliary/additional heater. "00012" is only to be entered if specifically requested by customer => Page
01-91 (encoding control unit).
Software version "D49" is used for auxiliary/additional heaters with part number 4D0 265 105 and index "G" or "H". Part number and software version can be called up by way of "Interrogating control unit version" function with fault reader V.A.G 1551.

With code "00011", undervoltage cut-out takes place as soon as battery voltage learnt in "Basic setting" function is not reached in auxiliary heating mode. This temperature-dependent cut-out curve is learnt in "Basic setting" function=>Page
01-69.
With code "00012", undervoltage cut-out takes place as soon as battery voltage entered in "Adaption" function is not reached in auxiliary heating mode.
If "Undervoltage cut-out (fixed value)" is displayed as fault for auxiliary/additional heater encoded to "00011":

- Encode auxiliary/additional heater to "00012" => Page
01-91 (encoding control unit).

- Use adaption function to read out value entered for undervoltage cut-out (fixed value) => Page
01-133 (adaption).

- Alter fixed value by way of "Adaption" function (specification less than 10.5 V).

- Encode auxiliary/additional heater to "00011" => Page
01-91 (encoding control unit).

Encoding of additional heater (with control unit -J162 as of software version "D49"):

Code · Significance
0 · 0 · 0 · 0 · 2 · - No recirculating pump -V55 fitted / Undervoltage cut-out is effected at voltage value entered in adaption function

Notes:

Code "00002" is always to be entered for heaters used as additional heater only.
Software version "D49" or higher is used for additional heaters with part number 4D0 265 071 as of index "B". Part number and software version can be called up by way of "Interrogating control unit version" function with fault reader V.A.G 1551.
If an additional heater is replaced with an auxiliary heater (with no recirculating pump), recirculating pump must additionally be fitted with software version "D49". With this software version, recirculating pump selection cannot be cancelled by way of encoding (only auxiliary heater version is available as replacement part).

Encoding of auxiliary/additional heater (with control unit -J162 as of software version "D50"):

Code · Significance
0 · No assignment
0 · No assignment
Vehicle version
0 · Auxiliary heater in vehicle with no coolant shut-off valve -N279 / (large coolant circuit)
1 · Auxiliary heater in vehicle with coolant shut-off valve -N279 / (small coolant circuit)
Auxiliary heater recirculating pump -V55
0 · Not installed / (Additional heater for vehicles with diesel engine only)
1 · Installed / (Auxiliary/additional heater)
Nature of undervoltage cut-out
1 · Undervoltage cut-out is effected at voltage value learnt in basic setting function
2 · Undervoltage cut-out is effected at voltage value entered in adaption function

Notes:

For encoding nature of undervoltage cut-out, heed notes on Page
01-34 (same as for software "D49").
If a vehicle provided at the factory with an auxiliary heater with software version "D49" and retrofitted with a small coolant circuit is fitted with an auxiliary heater as of software version "D50", this auxiliary heater is to be encoded - contrary to usual procedure - to "00011" for vehicle with large coolant circuit (no coolant shut-off valve) or vehicle electrical system is to be converted accordingly. => Refer to Page
82-305 and appropriate current flow diagram for vehicles with auxiliary heater and factory-fitted small coolant circuit in Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder (e.g. current flow diagram no. 39 for Model Year 2002 vehicles).
As of January 2000, coolant circuit is gradually being converted on vehicles with 8-cyl. petrol engine. Following introduction of coolant shut-off valve -N279 (modified coolant circuit), auxiliary heater coolant is no longer drawn in via engine in auxiliary heating mode (small coolant circuit).
When auxiliary heater is encoded for a small coolant circuit, a square-wave signal is emitted via output for actuation of fresh-air blower (operating and display unit for air conditioner/Climatronic -E87). This signal is processed by coolant shut-off valve relay -J541 (-E87 cannot process signal). This signal is used to output temperature of coolant in auxiliary heater and instantaneous auxiliary heater operating status. A positive signal is output if auxiliary heater is encoded for large coolant circuit (as for software versions "D49" and "D48") =>Page
01-205.

All vehicles with 12-cyl. engine are fitted with coolant shut-off valve -N279.
Software version "D50" or above is used for auxiliary/additional heaters with part number 4D0 265 105 and index "J" or "K". Part number and software version can be called up by way of "Interrogating control unit version" function with fault reader V.A.G 1551.
Auxiliary heaters with part number as of index "K" or "J" with software version "D52" have been gradually introduced into production since April 2001. With these auxiliary heaters, actuation of recirculating pump may be modified depending on encoding and adaption in adaption channel "10".
With code "000XX" (large coolant circuit), output of recirculating pump is reduced up to a coolant temperature of approx. 72 °C so as to increase temperature of coolant exiting from auxiliary heater (actuation time approx. 20 % at less than 60 °C and 100% at greater than 72 °C).
With code "001XX" (small coolant circuit), output of recirculating pump is also reduced as a function of coolant temperature => Page
01-133.
If, on vehicles with diesel engine, auxiliary/additional heater is not switched on and only recirculating pump -V55 starts up instead, check adaption in adaption channel "10" => Page
01-133.
If, on vehicles with petrol engine, auxiliary/additional heater is switched on as additional heater, check adaption in adaption channel "10" => Page
01-133.
If, on vehicles with petrol engine and coolant shut-off valve -N279, auxiliary heater is switched on as additional heater, also check encoding of auxiliary heater. If auxiliary heater is encoded for a vehicle with no shut-off valve and earth is applied to contact "3" in 6-pin connector to auxiliary heater (via coolant shut-off valve relay -J541), auxiliary heater is switched on as additional heater => Page
01-133.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.