🧭 Before you start

Models recorded for this source: Audi A5 (8T, 2007–2016), Audi Q5 (8R, 2008–2017), Audi A2 (8Z), Audi A3 (8L, 1996–2003), Audi A4 B5 (8D), Audi A4 B6/B7 (8E), Audi A4 B9 (8W, 2015–), Audi R8 (4S, 2015–), Audi A5 Cabriolet (8F), Audi A6 C5 (4B), Audi A8 D2 (4D), Audi A8 D3 (4E, 2002–2010), Audi A3 (8P, 2003–2012), Audi A4 Cabriolet B6/B7 (8H), Audi TT Mk1 (8N), Audi A6 C6 (4F, 2004–2011), Audi A4 B8 (8K, 2007–2015), Audi Q7 (4L, 2005–2015), Audi A3 (8V, 2012–2020), Audi Q7 (4M, 2015–), Audi A8 D4 (4H, 2010–2017), Audi TT Mk2 (8J, 2006–2014), Audi A6/A7 C7 (4G, 2011–2018), Audi A1 (8X, 2010–2018), Audi Q3 (8U, 2011–2018)

Don't miss

  • Only screw in the handwheel of the quick-release coupling adapters to the extent required to reliably open the valve at the refrigerant circuit connection (observe pressure gauge, do not open valve too far).

📋 Procedure

  1. Switch off ignition.
  2. Connect air conditioner service station to power supply.
  3. Assemble adapter set and screw onto connection on low-pressure side.
  4. Connect quick-release coupling adapters to the charging hoses of the air conditioner service station (handwheels not screwed in/hand shut-off valve not open).
  5. Switch on the air conditioner service station and evacuate the charging hoses (only necessary if there is air in the charging hoses).
  6. Switch off air conditioner service station.
  7. Unscrew the sealing cap from the service connection or the connection with valve (or remove the low-pressure switch and jumper the corresponding electrical connections).
  8. Connect air conditioner service station to vehicle refrigerant circuit via service connections with quick-release coupling adapters.
  9. Only screw in the handwheel of the quick-release coupling adapters to the extent required to reliably open the valve at the refrigerant circuit connection (observe pressure gauge, do not open valve too far).
  10. Perform planned tests and measurements.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.