🧭 Before you start

Models recorded for this source: Audi A8 D2 (4D)

  • Special tools named: V.A.G 1348/2B

Don't miss

  • The return manifold between cylinder 5 and the fuel temperature sensor must be sealed off with 3094;Schlauchklemmen bis Ø 25 mm to stop fuel escaping at the disconnected return pipes.
  • Press the return pipe connections carefully over the seal onto the injector. The seal must engage. Then secure the connections with retaining clips.
  • Run engine at idling speed for several minutes (do not press accelerator) and then switch off. Fuel system is bled automatically.
  • If there is still air in the fuel system, the engine may switch to emergency running mode during the test drive. Switch off the engine and erase the fault memory. Then continue with the test drive.

🔧 Engine codes recorded for this source

AKF

📋 Procedure

  1. Detach retaining clips of return pipes.
  2. Detach return pipes at all four injectors and attach four hoses (approx. 90 cm long) to return connections.
  3. Secure hoses with retaining clips again.
  4. The return manifold between cylinder 5 and the fuel temperature sensor must be sealed off with 3094;Schlauchklemmen bis Ø 25 mm to stop fuel escaping at the disconnected return pipes.
  5. Feed the hoses into V.A.G 1348/2B;Messgerät.
  6. Start engine.
  7. If the return flow rate of one or more injectors is so high that the engine will not start or is very difficult to start, this already becomes apparent when operating the starter from the considerable difference in the extent to which the measuring tubes are filled.
  8. If the engine starts, there should only be a minimal difference between the return flow rates of all four return pipes with the engine warm and idling at about 650 rpm.
  1. Press the return pipe connections carefully over the seal onto the injector. The seal must engage. Then secure the connections with retaining clips.
  1. Run engine at idling speed for several minutes (do not press accelerator) and then switch off. Fuel system is bled automatically.
  2. Check the entire fuel system for leaks.
  1. Then perform a test drive, accelerating at least once to full load before checking the high-pressure section again for leaks. [Note: If there is still air in the fuel system, the engine may switch to emergency running mode during the test drive. Switch off the engine and erase the fault memory. Then continue with the test drive.]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.