Checking relay for fuel cooling pump V166: Audi
Checking relay for fuel cooling pump V166 — Audi. Original source text. Read the instructions and application notes; confirm the exact vehicle before use.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
Checking
relay for fuel cooling pump
V166
Special tools and workshop equipment required
Portable multimeter
V.A.G 1526 B or
V.A.G 1526 A
Voltage tester
V.A.G 1527 B
Adapter set
V.A.G 1594 C or
V.A.G 1594 A
Test box
V.A.G 1598/30
Vehicle diagnostic, testing and information system
VAS 5051 A with diagnostic wire
VAS 5051/1
Test conditions
Fuse S4 OK (in fuse box, fuse carrier
ST4
- blue)
Vehicle diagnostic, testing and information system
VAS 5051 A with diagnostic wire
VAS 5051/1 connected, vehicle self-diagnosis and vehicle system
“01 - Engine electronics” selected; when doing this, the ignition must be switched on
Fault memory interrogated
Test sequence
Display on
VAS 5051 A
In list (1) select function
“03 - Final control diagnosis”.
Keep touching
→ key until fuel cooling pump relay
J445 is actuated.
The fuel cooling pump relay
J445 (in electronics box in passenger's footwell) must be energised (click) intermittently and the fuel cooling pump
V166 must run intermittently (can be heard at right of engine compartment).
Terminate function
“03 - Final control diagnosis” by touching
← key and switch off ignition.
A - If relay is not energised:
Check power supply of fuel cooling pump relay
J445.
Check actuation of fuel cooling pump relay
J445.
B - If relay is energised but fuel cooling pump does not run:
Check power supply for fuel cooling pump
V166.
Checking power supply of fuel cooling pump relay
J445
Take out floor covering in front right footwell.
Screw out bolts for electronics box cover (arrows) and detach cover.
Detach fuel cooling pump relay
J445 (arrow).
First connect up multimeter (voltage measuring range) between relay socket contact (2) and earth and then between relay socket contact (6) and earth.
Switch on ignition.
Specification: Approx. battery voltage in each case
If reading does not match specification:
Use current flow diagram to repair wiring.
Checking actuation of fuel cooling pump relay
J445
Connect up voltage tester
V.A.G 1527 B between relay socket contact (4) and battery positive.
Repeat function
“03 - Final control diagnosis”.
Keep touching
→ key until fuel cooling pump relay
J445 is actuated.
LED must flash (does not go out completely).
Terminate function
“03 - Final control diagnosis” by touching
← key and switch off ignition.
If LED flashes but relay is not energised:
Replace fuel cooling pump relay
J445.
If LED does not flash:
Switch off ignition.
Slacken off cross-head bolts (1) at electronics box in plenum chamber.
Unclip plenum chamber cover (2) at front at bulkhead (arrows).
Detach plenum chamber cover.
Prise out cover (1) in scuttle panel trim and slacken off rear cross-head bolt rear right arrow.
Slacken off the remaining cross-head bolts (arrows).
Detach cover for electronics box in plenum chamber.
Screw out bolt (arrow).
Disengage retainer.
Detach diesel direct injection system control unit 2
J494
Item 2
. Release and unplug connectors.
With ignition switched off, connect test box
V.A.G 1598/30 to connectors of diesel direct injection system control unit 2
J494 only (not to actual control unit).
Check for open circuit and short to earth or positive in the following wiring:
Relay socket
Contact
Test box
V.A.G 1598/30
Socket (4)
2/02
Repair wiring if necessary.
If no fault is found in wire:
Replace engine control unit.
Checking power supply for fuel cooling pump
On vehicles with auxiliary heater, screw out bolts (arrows) for attaching exhaust pipe of auxiliary/supplementary heater to noise insulation.
Unfasten quick-release fasteners (1) and detach front noise insulation.
Unplug connector (arrow) at fuel cooling pump.
Connect up voltage tester
V.A.G 1527 B between contacts (1) and (2).
Repeat function
“03 - Final control diagnosis”.
Keep touching
→ key until fuel cooling pump relay
J445 is actuated.
The LED must flash.
Terminate function
“03 - Final control diagnosis” by touching
← key and switch off ignition.
If LED does not flash:
Check for open circuit in wiring between connector of fuel cooling pump and fuel cooling pump relay
J445 (in electronics box in passenger's footwell).
Check for open circuit in wiring between connector of fuel cooling pump
V166 and earth point.
If no fault is found:
Replace fuel cooling pump.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Checking fuel cooling pump -V166 – Audi 1.9 TDI AJM/ATJ
- Checking fuel cooling pump V166 - vehicles with engine code letters AJM
- Checking actuation of fuel pump relay – Audi A3 1.6
- Checking electric fuel pump 2 relay J49 and activation - vehicles with 8-cylinder engine
- Checking fuel pump relay – Audi 1.8 ADR/AFY
- Checking fuel pump relay and actuation – Audi 1.8 AGU
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.