Checking output stage for ignition coil: Audi
Checking output stage for ignition coil — Audi. Original source text. Read the instructions and application notes; confirm the exact vehicle before use.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
Special tools and workshop equipment required
V.A.G 1526 A
V.A.G 1527 B
V.A.G 1594 A
V.A.G 1598 A
V.A.G 1598/3
Test requirement:
Ignition coil OK; checking => Page
28-12
Checking power supply
Unplug connector -item
28-4 at output stage.
Connect up multimeter for voltage measurement between contacts 1 (positive) and 3 (earth).
Switch on ignition.
Specification: approx. battery voltage
If reading does not match specification:
Connect up multimeter for voltage measurement as follows.
Connector / Contact · Measure to
1 (positive) · Engine earth
3 (earth) · Battery positive
Switch on ignition.
Specification: approx. battery voltage in each case
If readings do not match specifications:
Use current flow diagram to eliminate open circuit in wiring.
Checking actuation
Test requirement:
Hall sender OK; checking => Page
28-29
Unplug connector at injection unit to prevent catalytic converter damage.
Unplug connector -item
28-4 at output stage.
Connect up voltage tester V.A.G 1527 B between contacts 1 and 2.
Briefly operate starter.
LED must flash
If LED does not flash:
With ignition switched off, use adapter V.A.G 1598/3 to connect test box V.A.G 1598 A to engine control-unit connector only (not to control unit) => Page
24-20.
Check for open circuit and short to earth/positive in the following wiring.
Connector / Contact · Test box V.A.G 1598 A / Socket
2 · 13
Additionally check wires for mutual short circuit.
If necessary, eliminate open circuit in wiring/short circuit.
=> "Current Flow Diagrams, Electrical Fault-finding and Fitting Locations" binder
If wiring is OK:
Replace engine control unit => Page
24-23.
If power supply and actuation are OK:
Switch off ignition.
Re-attach connector and ignition cable at ignition coil.
Connect voltage tester V.A.G 1527 B with test leads and terminals to contacts 1 and 15 at ignition coil.
Attention:
When performing following test, avoid contact with connecting elements of ignition coil and test leads.
Operate starter.
LEDs must flash
If LEDs do not flash:
Replace combined ignition coil and output stage component.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Checking output stage for ignition transformer
- Removing and installing ignition coils with output stage
- Testing ignition coils -N, -N128 and -N158 with output stage -N122
- Checking ignition coils and output stages – Audi 2.2 AAN
- Checking ignition coils and output stages on vehicles with engine code "“AJK”", "“ARE”" and "“AZA”"
- Checking ignition coils and output stages on vehicles with engine code "“BES”"
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.