TorqFix

Checking output stage for ignition coil: Audi

Checking output stage for ignition coil — Audi. Original source text. Read the instructions and application notes; confirm the exact vehicle before use.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

Special tools and workshop equipment required

V.A.G 1526 A
V.A.G 1527 B
V.A.G 1594 A
V.A.G 1598 A
V.A.G 1598/3

Test requirement:

Ignition coil OK; checking => Page
28-12

Checking power supply

Unplug connector -item
28-4 at output stage.

Connect up multimeter for voltage measurement between contacts 1 (positive) and 3 (earth).
Switch on ignition.
Specification: approx. battery voltage

If reading does not match specification:

Connect up multimeter for voltage measurement as follows.

Connector / Contact · Measure to
1 (positive) · Engine earth
3 (earth) · Battery positive

Switch on ignition.
Specification: approx. battery voltage in each case

If readings do not match specifications:

Use current flow diagram to eliminate open circuit in wiring.

Checking actuation

Test requirement:

Hall sender OK; checking => Page
28-29

Unplug connector at injection unit to prevent catalytic converter damage.
Unplug connector -item
28-4 at output stage.

Connect up voltage tester V.A.G 1527 B between contacts 1 and 2.
Briefly operate starter.
LED must flash

If LED does not flash:

With ignition switched off, use adapter V.A.G 1598/3 to connect test box V.A.G 1598 A to engine control-unit connector only (not to control unit) => Page
24-20.

Check for open circuit and short to earth/positive in the following wiring.

Connector / Contact · Test box V.A.G 1598 A / Socket
2 · 13

Additionally check wires for mutual short circuit.
If necessary, eliminate open circuit in wiring/short circuit.

=> "Current Flow Diagrams, Electrical Fault-finding and Fitting Locations" binder

If wiring is OK:

Replace engine control unit => Page
24-23.

If power supply and actuation are OK:

Switch off ignition.
Re-attach connector and ignition cable at ignition coil.

Connect voltage tester V.A.G 1527 B with test leads and terminals to contacts 1 and 15 at ignition coil.

Attention:
When performing following test, avoid contact with connecting elements of ignition coil and test leads.
Operate starter.
LEDs must flash

If LEDs do not flash:

Replace combined ignition coil and output stage component.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.