📋 Procedure

Checking
fuel system pressurisation pump
G6
- vehicles with 5-cyl. engine
Special tools and workshop equipment required
Pressure tester
VAS 6550 with hoses
VAS 6550/1 and
VAS 6550/2
Pressure control valve
VAS 6550/4
Vehicle diagnostic tester
Fuel-resistant measuring container
A - Checking fuel delivery rate
Observe test conditions (see the separate procedure).
Release and open tank flap.
Clean area around fuel filler neck.
Remove filler cap (2) for fuel filler neck (1).
Note
Disregard item 3.
WARNING
Risk of injury - fuel system operates under high pressure.
To reduce the pressure in the fuel system, wrap a clean cloth around the connection and carefully loosen the connection.
Disconnect fuel line (1)
. Disconnecting plug-in connectors (see the separate procedure)
Note
Disregard item 2.
Connect pressure tester
VAS 6550 to fuel supply line with hose
VAS 6550/2.
Attach pressure control valve
VAS 6550/4 and hold end of hose into fuel-resistant measuring container.
Switch on pressure tester
VAS 6550 item 1 by pressing
On/Off button.
Note
To measure the fuel delivery rate, pressure must first be built up in the fuel line; the fuel pump must then operate against this pressure during the measurement. This pressure can be built up using the pressure control valve
VAS 6550/4 as follows:
Open cut-off valves
A and B.
Levers must point in direction of flow.
Caution
Risk of fuel escaping.
Cut-off valve (C) must be closed.
The lever should point perpendicular to direction of flow.
Connect vehicle diagnostic tester.
Switch on the ignition and select the following menu options on the vehicle diagnostic tester:
Vehicle self-diagnosis
Engine electronics
Basic setting
Empty fuel tank
Press
Start
: The fuel pump will start running.
Build up pressure in fuel system by turning adjuster screw (1) on pressure control valve
VAS 6550/4 until correct pressure is reached.
Specification: 4.5 bar
From this point on, do not turn adjuster screw (1).
Press
Stop.
Drain measuring container.
For measurement, press
Start again and let fuel pump run for 15 seconds.
Press
Stop after 15 seconds.
Check amount of fuel delivered in measuring container.
Specification: minimum delivery rate 700 cm (3)
/15 sec.
If the minimum delivery rate is attained:
Fuel delivery unit with fuel supply line is OK.
If minimum delivery rate is not achieved, check for the following causes:
Fuel delivery unit is defective.
Fuel supply line crushed.
Note
To find the precise cause of the fault, a pressure test must be performed on the fuel supply line as described below.
B - Pressure test on fuel supply line
Leave measuring equipment connected in the same way as for measuring the fuel delivery rate.
Vehicle diagnostic tester still connected.
Switch on pressure tester
VAS 6550 item 1 by pressing
On/Off button.
Open cut-off valves
A and B.
Levers must point in direction of flow.
Caution
Risk of fuel escaping.
Cut-off valve (C) must be closed.
The lever should point perpendicular to direction of flow.
Press
Start on vehicle diagnostic tester display to start the fuel pump.
When fuel emerging is free of bubbles, close cut-off valve (B) to allow fuel pressure to build up.
The lever should point perpendicular to direction of flow.
Read fuel pressure off pressure tester
VAS 6550:
Specification: at least 6.0 bar
If specification is attained although fuel delivery rate was not OK:
Fuel filter integrated in fuel delivery unit blocked or fuel supply line crushed.
If specification is not attained:
Fuel delivery unit is defective.
C - Checking residual pressure
Check system for leaks and check residual pressure by watching drop in pressure on pressure tester
VAS 6550:
After 10 minutes pressure should still be at least 3 bar.
If the residual pressure drops below 3 bar:
Check fuel lines and their connections for leaks.
Non-return valve in fuel pump is leaking, renew fuel delivery unit (see the separate procedure).
Assembling
Installation is carried out in the reverse order; note the following:
The ignition must be switched off.
Note
Before removing the pressure tester (1)
, release the fuel pressure by opening the cut-off valves
B, C and allowing fuel to drain off into a measuring container.
Detach pressure tester
VAS 6550 together with connection leads.
Connect fuel supply line, making sure it engages audibly.
Press fuel supply line in again and then pull to check that plug-in connector is correctly engaged.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.