TorqFix

Checking exhaust gas recirculation cooler for leaks: Audi A1 (8X) (CUSB)

Checking exhaust gas recirculation cooler for leaks — Audi A1 (8X) (CUSB). 18 source steps. Check the document conditions against your vehicle.

18 steps 1 engine code Showing one source document; this title group contains 8 variants

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A1 (8X, 2010–2018)

Don't miss

  • Set turbocharger testerV.A.G 1397A to switch position »II« (relative pressure measurement) and switch it on. The »II« must be visible.
  • A small amount of air escapes through the valves and enters the engine. Therefore it is not possible to perform a pressure retention test.
  • After the leak test has been completed, the Y-connectorVAS 691 005/1 must be cleaned to remove any water which may have entered.

🔧 Engine codes recorded for this source

📋 Procedure

  1. Fit test adapter VAS 691 005/5 onto coolant expansion tank.
  2. Fit Y-connector VAS 691 005/1 onto test adapter VAS 691 005/5.
  3. Close valve (1) for connection »C« and open valve (2) for connection »A«.
  4. Attach hose from connection »A« on Y-connector to connection »II« on turbocharger tester V.A.G 1397A.
  5. Set turbocharger tester V.A.G 1397A to switch position »II« (relative pressure measurement) and switch it on. The »II« must be visible.
  1. Loosen clamp (1) on exhaust pipe and push to rear (arrow).
  2. Connect adapter V.A.G 1687/11 with hose (A) to exhaust pipe (engine end). Secure hose with hose clips.
  1. Connect charge air system tester V.A.G 1687 to adapter V.A.G 1687/11.
  1. Unscrew pressure control valve (2) completely and close valves (3) and (4).
  1. Connect charge air system tester V.A.G 1687 to compressed air hose (1).
  2. If there is water in sight glass, remove drain plug (6) and drain water.
  3. Open valve (3).
  4. Adjust pressure to 0.5 bar via pressure control valve (2).
  5. Open valve (4) and wait until test system is pressurised. If necessary, adjust pressure to 0.5 bar again. [Note: A small amount of air escapes through the valves and enters the engine. Therefore it is not possible to perform a pressure retention test.]
  1. If pressure displayed on turbocharger tester rises, this means that compressed air is escaping from the exhaust end into the cooling system. There is a leak in exhaust gas recirculation cooler; renew exhaust gas recirculation cooler. [Note: After the leak test has been completed, the Y-connector VAS 691 005/1 must be cleaned to remove any water which may have entered.]
  1. Insert cleaning nozzle (D) in hose from connection (A) on Y connector.
  2. Fit compressed air hose on connection (C).
  3. Open cut-off valves and and blow through hose for approx. 15 seconds.

📐 5 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 5 workshop diagrams for this job Ask about your Audi CUSB — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.