🧭 Before you start

Models recorded for this source: Audi A3 (8V, 2012–2020)

Don't miss

  • Measure ambient temperature: It must be over 15 °C.
  • On vehicles with a high-voltage system, it is not necessary for the engine to be running when the cooling output test is performed (electrical air conditioner compressor V470).
  • Check activation and operation of N541 (it must not be activated) ("“Guided Fault Finding”").
  • Check installation position of N541 (arrow must point in flow direction of refrigerant from condenser to expansion valve) .
  • Perform Fault Finding measures to be taken if results do not match specification .

📋 Procedure

  1. ⚠ When working on a vehicle with the ignition switched on or while the drive system is active, the engine can start unexpectedly and exhaust fumes can cause a health hazard in closed rooms. Moving parts can trap or draw in parts of the body and/or clothing (safety hazard). Before switching on the ignition, perform the following steps:Move selector lever to position PActivate parking brake Switch off ignitionOpen bonnetConnect battery charger (e.g. VAS 5095A) to jump-start connections of 12 V electrical system Switch on ignition — To minimise the number of automatic engine starts when the vehicle's drive system is active during test and measurement work, charge the vehicle batteries e.g. with the battery charger 60AVAS 5904 in battery standby mode Electrical system; General information 27. Battery; Charging battery and 4-cylinder direct injection engine (1.2, 1.4 ltr. 4-valve TFSI EA 211)00Safety precautions; Safety precautions when working on high-voltage vehicles.
  2. For test and measurement work that requires the vehicle's drive system to be active (READY) or the ignition to be switched on, move the selector lever to position "“P”", activate the parking brake and take care to keep well clear of the engine when it is running. Set up any tools needed so that they cannot come into contact with moving parts. [Note: Also move the selector lever to position "“P”" and activate the parking brake before performing test and measurement work for which the ignition must be switched on but where the vehicle's drive system does not need to be active (READY).The status of the drive system (READY) is shown by the control unit in dash panel insert J285 via the "“power meter”"Owner's Manual. Activating and deactivating drive system Owner's Manual (note display of control unit in dash panel insert J285).]
  1. Measure ambient temperature: It must be over 15 °C.
  2. Close doors, bonnet, windows, sunroof and rear lid.
  3. Open all dash panel vents and any vents in rear centre console. [Note: The status of the drive system (READY) is shown by the control unit in dash panel insert J285 via the "“power meter”".Activating vehicle drive system (check "READY" display in control unit in dash panel insert J285) Owner's ManualMove the selector lever to position "“P”" and activate the parking brake before performing test and measurement work for which the ignition must be switched on but where the vehicle's drive system does not need to be active.]
  1. Ignition is switched on and drive system is active (READY), engine only starts or runs if e.g. hybrid battery unitAX1 is not sufficiently charged. [Note: On vehicles with a high-voltage system, it is not necessary for the engine to be running when the cooling output test is performed (electrical air conditioner compressor V470).]
  1. Switch off air conditioner compressor on operating unit (Climatronic control unit J255): Lamp in A/C button (8) not on.
  2. "“Read measured values”" ("“Guided Fault Finding”"). [Note: Various measured values can be selected in the Guided Fault Finding routine for the following test and displayed in a table ("“Guided Fault Finding”").The electrical air conditioner compressor V470 is supplied with electric power via a fuse fitted in the power and control electronics for electric driveJX1Removing and installing fuse for electrical air conditioner compressor, 4-cylinder direct injection engine (1.2, 1.4 ltr. 4-valve TFSI EA 211)93Power and control electronics for electric drive and .] [Note: On the absolute pressure scale, 0 bar corresponds to an absolute vacuum. Normal ambient pressure thus corresponds to approx. 1 bar absolute and 0 bar gauge pressure. On the scales of most pressure gauges, 0 bar gauge pressure corresponds to an absolute pressure of 1 bar (can be seen from -1 mark below 0).Depending on the version of the air conditioner operating unit (Climatronic control unit J255), the measured values may only be displayed as whole numbers. The display fluctuates between two values if the measured pressure is between the two. The displays for the activation of the air conditioner compressor differ. For a mechanically driven air conditioner compressor, the tester displays the specified and actual current for activation of the air conditioner compressor regulating valve N280. The specified speed of the electrical air conditioner compressor V470 calculated by J255 and transmitted to the control unit for air conditioner compressor J842 and its actual speed determined by J842 are displayed in a measured value ("“Guided Fault Finding”" for air conditioner).The pressure in the refrigerant circuit depends on the ambient temperature. Due to the radiation of heat by components (e.g. radiator), the pressure displayed when the engine is warm is slightly higher than that given for the corresponding ambient temperature.]
  1. Check signal from G805 or G395 (depending on vehicle version) ("“Guided Fault Finding”").
  1. The necessary work may only be performed by appropriately qualified personnel. If this is not possible on your premises, the vehicle must be taken to a workshop equipped with the necessary tools where this work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a 87. General notes on air conditioning systems. Inform the workshop of the problem detected.
  1. Make the following settings on operating unit J255:
  1. "“Read measured values”" ("“Guided Fault Finding”").
  2. Check display in display zones: [Note: The specified speed for V470 is calculated by the air conditioner operating unit (Climatronic control unit J255). The request is transmitted via the data bus to the control unit for air conditioner compressor J842 ("“Guided Fault Finding”").When driving, the air conditioner compressor operates over a speed range of 800 to 8600 rpm. When the vehicle is stationary or only moving slowly (up to a speed of approx. 45 km/h), the air conditioner compressor is not activated at the maximum specified speed (of approx. 8500 rpm); the air conditioner compressor speed is limited to approx. 5000 rpm. The electrical air conditioner compressor V470 is supplied with electric power via a fuse fitted in the power and control electronics for electric driveJX1Removing and installing fuse for electrical air conditioner compressor, 4-cylinder direct injection engine (1.2, 1.4 ltr. 4-valve TFSI EA 211)93Power and control electronics for electric drive and .At an air conditioner compressor speed of 5000 rpm, with a very high ambient temperature (in excess of 35 ℃) and a high fresh air blower speed (unfavourable ambient conditions), the output (delivery volume) of the air conditioner compressor is at first not always sufficient to reduce the temperature of the air downstream of the evaporator to the specified value. One way of checking the control action of the air conditioner compressor under these conditions is to activate the fresh air blower with only approx. 40 % of the maximum voltage and to check the temperature at reduced fresh air blower speed ("“Guided Fault Finding”" for air conditioner).If an insufficient speed or no speed at all is displayed as the measured value (a speed of less than 4000 rpm although the required temperature of the air downstream of the evaporator has still not been reached), check the activation of the electrical air conditioner compressor V470 by the control unit for air conditioner compressor J842 ("“Guided Fault Finding”").N541 and N542 are open (de-energised). N541 is activated e.g. when the air conditioner does not request any cooling output, but the hybrid battery unitAX1 (power and control electronics for electric driveJX1) needs to be cooled.N542 is activated e.g. when the air conditioner requests cooling output and AX1 and/or JX1 do not have to be cooled.]
  1. In the "“Read measured values”" function, read out the pressure in the refrigerant circuit measured by G805 or G395. The pressure displayed increases to above the value with the air conditioner compressor switched off ("“Guided Fault Finding”").
  1. Check activation and operation of N541 (it must not be activated) ("“Guided Fault Finding”").
  2. Check installation position of N541 (arrow must point in flow direction of refrigerant from condenser to expansion valve) (see the separate procedure).
  1. The necessary work may only be performed by appropriately qualified personnel. If this is not possible on your premises, the vehicle must be taken to a workshop equipped with the necessary tools where this work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a 87. General notes on air conditioning systems. Inform the workshop of the problem detected. [Note: The electrical air conditioner compressor V470 is activated by the control unit for air conditioner compressor J842 when requested by the air conditioner operating unit (Climatronic control unit J255) in such a way that the temperature of the air downstream of the evaporator reaches the specified value (approx. 2 to 6 ℃).After the engine is started, the air conditioner compressor is activated at a speed greater than 3000 rpm depending on the measured temperature, engine speed and electrical system voltage. As soon as the temperature measured by the evaporator output temperature sender G263 approaches the specified value, the activation is reduced and the compressor output is decreased. Under certain operating conditions, residual moisture in the refrigerant circuit may lead to the formation of ice at the expansion valve for the evaporator in the air conditioning unit. This ice formation can impair the control function of the expansion valve/air conditioner compressor. The evaporator is insufficiently or excessively cooled and may ice up. An iced-up evaporator may cause various problems .]
  1. Press Air recirculation button (10) on operating unit J255.
  1. "“Read measured values”" ("“Guided Fault Finding”").
  2. Compare measured value displayed for evaporator output temperature sender G263 to values in graph.
  1. Compare measured values for left vent temperature sender G150 and right vent temperature sender G151 to measured value displayed for evaporator output temperature sender G263 ("“Guided Fault Finding”"). [Note: You can also use a thermometer to measure the temperature of the air emerging from the dash panel vents (left and right).The operation of the air conditioner can be detected e.g. from the fact that the refrigerant pipe on the low-pressure side (thick pipe) cools down. When the vehicle is stationary or only moving slowly (up to a speed of approx. 45 km/h), the air conditioner compressor is not activated at the maximum specified speed (of approx. 8500 rpm); the air conditioner compressor speed is limited to approx. 5000 rpm. At an air conditioner compressor speed of 5000 rpm, with a high ambient temperature (in excess of 30 ℃) and a high fresh air blower speed (unfavourable ambient conditions), the output (delivery volume) of the air conditioner compressor is at first not always sufficient to reduce the temperature of the air downstream of the evaporator to the specified value. One way of checking the control action of the air conditioner compressor under these conditions is to activate the fresh air blower with only approx. 40 % of the maximum voltage and to check the temperature at reduced fresh air blower speed ("“Guided Fault Finding”" for air conditioner).]
  1. Perform Fault Finding measures to be taken if results do not match specification (see the separate procedure).
  1. Check that G263 is correctly installed and perform electrical check for this sender ("“Guided Fault Finding”").
  1. Perform Fault Finding if results do not match specification (required cooling output is not attained) (see the separate procedure).
  1. Check activation of temperature flaps in air conditioning unit and ("“Guided Fault Finding”").
  1. Check activation and operation of N542; it must not be activated when cooling output is requested for cooling high-voltage system components Incorporation of heat exchanger for high-voltage battery into coolant circuit of high-voltage system and ("“Guided Fault Finding”").
  2. Check installation position of N542 (arrow must point in flow direction of refrigerant from condenser to heat exchanger for high-voltage battery) (see the separate procedure).
  3. Check connections between heat exchanger for high-voltage battery ("chiller") and coolant circuit of high-voltage system and 4-cylinder direct injection engine (1.2, 1.4 ltr. 4-valve TFSI EA 211)19Cooling system/coolant; Connection diagram - coolant hoses, cooling components for high-voltage system.
  4. Check operation and activation of coolant pump for high-voltage battery V590 and coolant valve for high-voltage battery N688Incorporation of heat exchanger for high-voltage battery into coolant circuit of high-voltage system, ("“Guided Fault Finding”" for hybrid battery energy management system) and 4-cylinder direct injection engine (1.2, 1.4 ltr. 4-valve TFSI EA 211)19Cooling system/coolant; Connection diagram - coolant hoses, cooling components for high-voltage system. [Note: In air conditioner control mode N542 is closed; it is activated by the air conditioner operating unit (Climatronic control unit J255). Only if there is a request for cooling output via the heat exchanger for the high-voltage battery from the hybrid battery unitAX1 and/or the power and control electronics for electric driveJX1 does J255 switch off the activation of N542; the refrigerant can then flow via the restrictor in the refrigerant line into the heat exchanger for the high-voltage battery and cool it. The hybrid battery unitAX1 is only cooled if the coolant pump for high-voltage battery V590 is also activated correctly. In order for the power and control electronics for electric driveJX1 and the control unit for high-voltage battery charging unit J1050 to be cooled, the coolant valve for high-voltage battery N688 and the coolant circulation pump before power and control electronics for electric drive V508 must also be activated correctly Incorporation of heat exchanger for high-voltage battery into coolant circuit of high-voltage system, ("“Guided Fault Finding”" for hybrid battery energy management system) and 4-cylinder direct injection engine (1.2, 1.4 ltr. 4-valve TFSI EA 211)19Cooling system/coolant; Connection diagram - coolant hoses, cooling components for high-voltage system. If the air conditioner operating unit (Climatronic control unit J255) detects a fault in the connection between J255 and N542, it switches off the activation of the electrical air conditioner compressor V470 (depending on version of J255); cooling output is then stopped. Depending on the version of the air conditioner operating unit (Climatronic control unit J255), N542 is not activated when the final control diagnosis for the electrical air conditioner compressor V470 is being performed so that the cooling output for the heat exchanger for the high-voltage battery can be checked during the diagnosis ("“Guided Fault Finding”").The refrigerant shut-off valve for high-voltage battery heat exchanger N542(A) is open (de-energised); this means that the heat exchanger for the high-voltage battery is cooled as long as N542 is not activated in air conditioning mode. If, with the ignition switched off, a different shut-off valve (with identical electrical values as N542(A) fitted) is connected, or if coil (B) is removed from shut-off valve (D), the cooling of the heat exchanger for the high-voltage battery can be checked without a fault being detected in J255Removing and installing heat exchanger for high-voltage battery. (Should it be necessary to unplug the electrical connector for coil (B) in order to detach the coil, remember to plug it in again.)Screws (C) must be removed to detach coil (B) (do not unplug connector with ignition switched on; if it has been detached plug it in again before switching on the ignition).If there is a complaint and the vehicle's cooling output is OK and the heat exchanger for the high-voltage battery is cooled correctly while N542 is not being activated, check the activation of N542 as well as the connections between the heat exchanger for the high-voltage battery and the low-temperature coolant circuit; also check the activation and operation of the corresponding components Incorporation of heat exchanger for high-voltage battery into coolant circuit of high-voltage system ("“Guided Fault Finding”" for hybrid battery energy management system) and 4-cylinder direct injection engine (1.2, 1.4 ltr. 4-valve TFSI EA 211)19Cooling system/coolant; Connection diagram - coolant hoses, cooling components for high-voltage system. If the vehicle's cooling output is OK and the heat exchanger for the high-voltage battery is not being cooled while N542 is not being activated (or when coil (B) is detached), the cause could also be a blocked restrictor in refrigerant line (E).]
  1. If there is a fault in the refrigerant circuit, the necessary work may only be performed by appropriately qualified personnel. If this is not possible on your premises, the vehicle must be taken to a workshop equipped with the necessary tools where this work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a 87. General notes on air conditioning systems. Inform the workshop of the problem detected.

📐 2 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 2 workshop diagrams for this job Ask about your Audi — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.