📋 Procedure

Special tools, testers and auxiliary equipment required

Fault reader V.A.G 1551 (or vehicle system tester V.A.G 1552) with cable V.A.G 1551/3
Minitester V.A.G 1362

Test requirements:

Cooler and condenser clean; clean if necessary
Ribbed belt for compressor drive OK and correctly tensioned.
All air ducts, covers and seals are OK and properly fitted.
Air flow through dust and pollen filter not impeded by dirt.
Connection between evaporator and heating does not draw in any secondary air at maximum fresh-air blower speed.
Vehicle is not exposed to sunlight.

Engine at operating temperature.
Fault memory interrogated => Page
01-67.
Coding checked and corrected if necessary => Page
01-69.
Basic setting performed => Page
01-63.
All dash panel vents open
Settings on operating and display unit -E87:
"Auto" mode
"LO" temperature selected
Compressor on (frost symbol illuminated in the display /telltale in the "ECON" button not lit)

Functions with engine running:
Compressor is driven (the magnetic clutch is engaged).
Radiator fan -V7 running (at least speed 1).

Fresh-air blower -V2 running at maximum speed.
Fresh-air and recirculated-air flap goes into "air recirculation mode" (approx. 1 minute after the vehicle is started).
Temperature flap is in the position "cooling".

Note:

If one of these conditions is not met, interrogate fault memory => Page
01-46.

Checking

A -
Air temperature from the "centre" dash panel vents
B -
Ambient temperature
C -
Permissible tolerance range

Depending upon the ambient temperature, the air temperature from the "centre" dash panel vents must be within the stated tolerance range within 5 minutes.

Close bonnet.
Measure the ambient temperature
Close the doors, windows and sunroof.

Close the "right" and "left" dash panel vents.
Switch the ignition on.
Open the "centre" dash panel vents.
Set the "auto" mode.
Preselect temperature "LO".
Start the engine.
Press the button for the recirculated-air flap (symbol for "air recirculation mode" in the right display or in the button is lit).
Increase the engine speed to 2000 rpm (start of time measurement).

Measure the temperature of the air flowing from the "centre" dash panel vents, e.g. with a Minitester V.A.G 1362.
Compare measured values with values in the diagram.

Notes:

It is recommended that two independent thermometers are used for this measurement.
If the required values are not attained => Page
87-123 (determine fault if specified value not attained).
During self-diagnosis, with an operating and display unit -E87 with Part No. 8D0 820 043 from index "D", the air conditioner control is no longer switched off.
The air temperature in the air conditioner's mixing chambers (downstream of heat exchanger) can be measured in the measured value block with V.A.G 1551 during the refrigeration capacity test =>display group 014, Page
01-128.
The function of the air conditioner may be recognised, for example, from the fact that the refrigerant pipe at the low-pressure end (thick pipe) cools down.
From Model Year 1997, the air conditioner pressure switch -F129 (=> Page
01-106.

Fault determination in the event of deviation from specified value

▪ Was the compressor switched off during the refrigeration capacity test?
↓ / yes / ↓ · ↓ / no / ↓
- Continue with test => Page 87-124 · - Use hose clamps 3093 or 3094 to pinch off the two coolant hoses from the engine to the heater's heat exchanger. / ↓
- Repeat the refrigeration capacity test =>Page . 87-118 / ↓
▪ Is the required refrigeration capacity attained?
↓ / yes / ↓ · ↓ / no / ↓
- Detach the hose clamps 3093 or 3094 on both coolant hoses. / ↓ · - Send the vehicle to an VW/Audi air-conditioning service centre (fault in refrigerant circuit).
- Check the actuation of the temperature flap positioning motor -V68, perform final control diagnosis=> Page . 01-55

Continuation of test - compressor was deactivated during the refrigeration capacity test
- Interrogate fault memory => Page . 01-110 / Repeat the refrigeration capacity test.
▪ Is the required refrigeration capacity attained (compressor was not switched off)?
↓ / yes / ↓ · ↓ / no / ↓ · ↓ / no / ↓
End · - Vehicles in which the control was not deactivated during the self-diagnosis: · - Vehicles in which the control was deactivated during the self-diagnosis:
↓ / Continued t · ↓ / Continued t

1)
Control deactivated during self-diagnosis.

2)
Control not deactivated during self-diagnosis.

↓ / In display zone 1, read the code for the compressor shutoff criterion according to which the compressor was shut off. · ↓ / Press the Q key on the V.A.G 1551 immediately the compressor is deactivated (the air conditioner control is deactivated and the compressor shutoff criterion stored).
- Read measured value block, display group 001 => Page 01-82
↓ / Code 1 / ↓ · ↓ / Code 3 / ↓ · ↓ / Other code / ↓
▪ High-pressure switch -F118/-F23 or pressure switch -F129 open · ▪ Low-pressure switch -F73 open or pressure switch -F129 open · ▪ =>from Page 01-110
↓ · ↓
- Continue the test / =>Page 87-126 · - Continue with test =>Page 87-127

Continuation of test - compressor shutoff criterion code "1"
▪ Was the radiator fan -V7 switched to speed 2 during the test?
↓ / yes / ↓ · ↓ / no / ↓
- Renew the high-pressure switch -F118/-F23 or the pressure switch -F129. / Repeat the refrigeration capacity test. / ↓ · - Jumper contacts "1" and "2" in the detached connector of the high pressure switch -F118/-F23 => Page 87-21 / ↓
▪ Is the required refrigeration capacity attained (compressor was not switched off)? · ▪ Is the radiator fan running at speed 2?
↓ / yes / ↓ · ↓ / no / ↓ · ↓ / yes / ↓ · ↓ / no / ↓
End · - Re-install the old switch. / -F118/-F23 or -F129. / Send the vehicle to an VW/Audi air-conditioning service centre (fault in refrigerant circuit). · - Renew the high-pressure switch -F118/-F23 or the pressure switch -F129. · - Service the fan -V7 actuation according to the current flow diagram / Repeat the refrigeration capacity test =>Page 87-118

Continuation of test - compressor shutoff criterion code "3"
- Jumper the contacts in the detached connector of the low-pressure switch -F73 => Page 87-118 / ▪ Is the required refrigeration capacity attained?
↓ / yes / ↓ · ↓ / no / ↓
- Replace the switch -F73 or -F129. · ▪ Was the compressor switched off again?
- Repeat the refrigeration capacity test. · ↓ · ↓
↓ / ▪ Is the required refrigeration capacity attained? · yes / ↓ · no / ↓
↓ / ↓ / yes / ↓ · ↓ / ↓ / no / ↓ · - Check the wiring to the operating and display unit -E87 via the switch -F73/-F129. · - Send the vehicle to an VW/Audi air-conditioning service centre (fault in refrigerant circuit).
End · - Re-install the old switch -F73 or -F129 / Send the vehicle to an VW/Audi air-conditioning service centre (fault in refrigerant circuit). · ↓ / Repeat the refrigeration capacity test.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.