🧭 Before you start

Models recorded for this source: Audi A6/A7 C7 (4G, 2011–2018)

Don't miss

  • Ensure requirements are met .
  • When fitting the wheel centre mountingsVAS 6350/1 onto the wheels, make sure that they are not mounted on any "“anti-theft”" wheel bolts that might be installed.

📋 Procedure

  1. Ensure requirements are met (see the separate procedure).
  2. Set up and align calibration unit VAS 6350 with calibration unit for overhead view camera VAS 6350/6.
  3. Connect (see the separate procedure).
  1. Check bolt circle of wheels.
  2. Prepare wheel centre mountings VAS 6350/1 as required. Use spacers.
  3. To do so, secure three wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match the hole circle.
  4. Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.
  5. Fit wheel centre mountings VAS 6350/1 onto wheel bolts on front wheels. [Note: When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that they are not mounted on any "“anti-theft”" wheel bolts that might be installed.]
  1. After setting up the calibration unit VAS 6350 with calibration unit for overhead view camera VAS 6350/6(4), position it next to the vehicle.
  2. Using clamping bolt, adjust paddle (2) so that it can move freely slightly above calibration field of calibration unit VAS 6350(4).
  1. Use ratchet (3/8-inch) to screw guide pin VAS 6350/6-5(2) into rear left wheel as far as stop and fit mounting for linear laser VAS 6350/6-6 together with linear laser VAS 6350/3(1).
  2. Slide mounting for linear laser VAS 6350/6-6 so that outer edge of guide pin VAS 6350/6-5 is flush with outer edge of laser housing (arrow) and pull lever tight.
  1. Switch on linear laser VAS 6350/3(3) and adjust laser beam forwards in direction of wheel centre mounting VAS 6350/1(2) so that a line appears on calibration field of calibration unit VAS 6350(4).
  2. Align calibration field of calibration unit VAS 6350(4) so that outer side of black line along length of calibration field of calibration unit VAS 6350(4) is located exactly on laser beam.
  3. Align calibration field of calibration unit VAS 6350(4) so that outer side of black line (1) aligns exactly with hanging paddle on wheel centre mounting VAS 6350/1(2).
  4. Move calibration unit VAS 6350 with calibration unit for overhead view camera VAS 6350/6 to a horizontal position.
  5. To do so, turn plastic feet beneath calibration field of calibration unit VAS 6350 to make air bubble in spirit level move exactly to centre of display (arrow).
  1. ⚠ Make sure no light is reflected on calibration unit for overhead view camera VAS 6350/6.Reflected light impairs the view of the cameras and therefore it may be impossible to perform calibration. — Measure height of calibration unit VAS 6350(2) (dimension (h)) from top surface of calibration field of calibration unit VAS 6350(2) (not aluminium frame) to floor. Perform the measurement at the hole provided in the calibration field of the calibration unit VAS 6350(2).
  1. Select Diagnosis mode and start diagnosis.
  2. Select Test plan tab.
  3. Select Own test then the following options one after the other:

📐 5 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 5 workshop diagrams for this job Ask about your Audi — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.