Bleeding clutch system — R tronic — Audi. 12 source steps. Read the instructions and application notes; confirm the exact vehicle before use.

12 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

  • Opens: clutch fluid, power steering fluid
  • Special tools named: V.A.G 1782

Don't miss

  • This is necessary to prevent hydraulic fluid from entering the clutch housing.
  • The hydraulic fluid that comes out when bleeding the system must not be used again.
  • When the system is bled, the clutch valve is activated at one-second intervals and the clutch is opened and closed repeatedly.Ensure bleeder hose is correctly fitted during bleeding operation.
  • If the vehicle diagnostic tester terminates the function "„Bleed clutch system“" before the end of this period, select the function Bleed clutch system once again.

📋 Procedure

  1. Remove air cleaner housing Injection and ignition system24.
  2. Seal off aperture on gearbox (arrow) with a clean cloth. [Note: This is necessary to prevent hydraulic fluid from entering the clutch housing.]
  1. Remove protective cap from bleeder screw (B) and fit bleeder hose (A).
  2. Place other end of bleeder hose in catch tray of used oil collection and extraction unit V.A.G 1782. [Note: The hydraulic fluid that comes out when bleeding the system must not be used again.]
  1. Using diagnostic tester in Guided Functions mode, select 02 - Gearbox electronics and the function Bleed clutch system. [Note: When the system is bled, the clutch valve is activated at one-second intervals and the clutch is opened and closed repeatedly. Ensure bleeder hose is correctly fitted during bleeding operation.]
  1. Open bleeder screw (B).
  1. Close bleeder screw (B). [Note: If the vehicle diagnostic tester terminates the function "„Bleed clutch system“" before the end of this period, select the function Bleed clutch system once again.]
  1. Repeat the bleeding procedure until no more air bubbles come out.
  2. Tighten bleeder screw (B).
  3. Disconnect bleeder hose (A) and fit protective cap on bleeder screw.
  4. Check fluid level in hydraulic unit for R tronic and top up as required (see the separate procedure).
  1. Install air cleaner housing Injection and ignition system24.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.